期刊文献+

Numerical Simulation of the Blood Flow through a Brain Vascular Aneurysm with an Artificial Stent Using the SPH Method

Numerical Simulation of the Blood Flow through a Brain Vascular Aneurysm with an Artificial Stent Using the SPH Method
下载PDF
导出
摘要 We present numerical simulations of blood flow through a brain vascular aneurysm with an artificial stent using Smoothed Particle Hydrodynamics (SPH). The aim of this work is to analyze how the flow into an aneurysm changes using different stent configurations. The initial conditions for the simulations were constructed from angiographic images of a real patient with an aneurysm. The wall shear stresses, pressure and highest velocity within the artery, and other particular quantities are calculated which are of medical specific interest. The numerical simulations of the cerebral circulation help doctors to determine if the patient’s own vascular anatomy has the conditions to allow arterial stenting by endovascular method before the surgery or even evaluate the effect of different stent structure and materials. The results show that the flow downstream the aneurysm is highly modified by the stent configuration and that the best choice for reducing the flow in the aneurysm is to use a completely extended Endeavor stent. We present numerical simulations of blood flow through a brain vascular aneurysm with an artificial stent using Smoothed Particle Hydrodynamics (SPH). The aim of this work is to analyze how the flow into an aneurysm changes using different stent configurations. The initial conditions for the simulations were constructed from angiographic images of a real patient with an aneurysm. The wall shear stresses, pressure and highest velocity within the artery, and other particular quantities are calculated which are of medical specific interest. The numerical simulations of the cerebral circulation help doctors to determine if the patient’s own vascular anatomy has the conditions to allow arterial stenting by endovascular method before the surgery or even evaluate the effect of different stent structure and materials. The results show that the flow downstream the aneurysm is highly modified by the stent configuration and that the best choice for reducing the flow in the aneurysm is to use a completely extended Endeavor stent.
出处 《Engineering(科研)》 2018年第12期891-912,共22页 工程(英文)(1947-3931)
关键词 BRAIN VASCULAR FLOW ANEURYSMS Blood FLOW Particle Methods Numerical Modeling Brain Vascular Flow Aneurysms Blood Flow Particle Methods Numerical Modeling
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部