期刊文献+

Research on the Method of Calculating Node Injected Reactive Power Based on L Indicator

Research on the Method of Calculating Node Injected Reactive Power Based on L Indicator
下载PDF
导出
摘要 With the power grid load increasing, the problem of grid voltage stability is increasingly prominent, and the possibility of voltage instability is also growing. In order to improve the voltage stability, this paper analyzed how the voltage stability was influenced by different reactive power injection based on the simplified L-indicator of on-line voltage stability monitoring. According to the basic differential property of the simplified L-indicator, a general and normative analytical algorithm about reactive power optimization was deduced. The analytical algorithm can calculate the load node injected reactive power, and then the network can run in the optimal steady state on the basis of the calculation results. According to the simulation results of IEEE-14, IEEE-30, IEEE-57 and IEEE-118, the feasibility and effectiveness of the proposed algorithm to improve voltage stability and reduce the risk of grid collapse were verified. With the power grid load increasing, the problem of grid voltage stability is increasingly prominent, and the possibility of voltage instability is also growing. In order to improve the voltage stability, this paper analyzed how the voltage stability was influenced by different reactive power injection based on the simplified L-indicator of on-line voltage stability monitoring. According to the basic differential property of the simplified L-indicator, a general and normative analytical algorithm about reactive power optimization was deduced. The analytical algorithm can calculate the load node injected reactive power, and then the network can run in the optimal steady state on the basis of the calculation results. According to the simulation results of IEEE-14, IEEE-30, IEEE-57 and IEEE-118, the feasibility and effectiveness of the proposed algorithm to improve voltage stability and reduce the risk of grid collapse were verified.
出处 《Journal of Power and Energy Engineering》 2014年第4期361-367,共7页 电力能源(英文)
关键词 VOLTAGE Stability L-Indicator Injected REACTIVE POWER REACTIVE POWER Optimization Fast Calculation Voltage Stability L-Indicator Injected Reactive Power Reactive Power Optimization Fast Calculation
  • 相关文献

参考文献6

二级参考文献24

  • 1孙刚,余贻鑫.一种新的优化潮流模型[J].电力系统及其自动化学报,2005,17(3):6-9. 被引量:3
  • 2李兴源,宋永华,刘俊勇,付英,曾敏.基于人工神经元网络的复杂电力系统故障后电压安全评估[J].中国电机工程学报,1996,16(3):147-150. 被引量:5
  • 3王秀英.电力系统电压稳定性分析和控制(Voltage stability analysis and control of power systems)[D].成都:四川大学(Chengdu:Sichuan University),1998.
  • 4Long B. Ajjarapu V, The sparse formulation of ISPS and application to voltage stability margin sensitivity and estimation[J]. IEEE Trans.Power Systems, 1999, 14(3): 944-957.
  • 5Chebbo M, Irving M R, M. Sterling J H, Voltage collapse proximity indicator: behavior and implications[J]. IEE Proc. Pt. C. 1992,139(4): 241-252.
  • 6Haque M H, A fast method for determining the voltage stability limit of a power system[J]. Electric Power System Research, 1995,32(1996): 35-43.
  • 7Fu Y, Chong T S, Li X Y, An improved approach to voltage stability analysis via network equivalence[A]. Procs. 4^th International Conference on Advances in Power System Control[C], Operation & Management (APSCOM), Hongkong. 1997, 1: 231-235.
  • 8Chung T. S, Fu Y, A fast voltage security assessment method via extended ward equivalent and neural network approach [J].IEEE Power Engineering Review, 1999, 19(10): 40-43.
  • 9Taylor C W, Power system voltage stability[M], New York: McGraw Hill, 1994.
  • 10Lof P A, Smed T. Andersson G, et al. Fast calculation of a voltage stability index[J].IEEE Trans. Power Systems, 1992, 6(1): 54-64.