期刊文献+

Optimal Control of a Thermoelectric Generator Attached with a Latent Heat Accumulator

Optimal Control of a Thermoelectric Generator Attached with a Latent Heat Accumulator
下载PDF
导出
摘要 Generally MPPT control (maximum power point tracking) is adopted to control of a thermoelectric generator. However, in the case of generation by use of a heat accumulator MPPT control cannot obtain maximum whole electrical output during the operation period. This is because the amount of heat stored in a heat accumulator is limited and easy to be exhausted rapidly by MPPT. Therefore MEPT (Maximum Efficiency Point Tracking) control should be developed to obtain maximum power from limited heat stored in the heat accumulator. When thermoelectric generator is used for waste heat recovery, conversion efficiency is quite difficult to be measured. This is due to time delay between the change of temperature profile in the thermoelectric generator and the change of heat medium temperature. Decrease of output current is desired to enlarge output because decrease of current decreases Peltier heat and improves efficiency of heat recovery. The experimental results indicate that current fluctuated by MPPT control causes loss of power output. We proposed the optimal control in which current is 10% smaller than one of MPPT control and evaluated it experimentally. We call this control scheme MEPT control. In this evaluation 500 W class thermoelectric generator, latent heat accumulator and the test facilities included 30 kW electric heater are utilized. Experimental result shows MEPT control exceeds MPPT in total electricity recovered from heat accumulator. Generally MPPT control (maximum power point tracking) is adopted to control of a thermoelectric generator. However, in the case of generation by use of a heat accumulator MPPT control cannot obtain maximum whole electrical output during the operation period. This is because the amount of heat stored in a heat accumulator is limited and easy to be exhausted rapidly by MPPT. Therefore MEPT (Maximum Efficiency Point Tracking) control should be developed to obtain maximum power from limited heat stored in the heat accumulator. When thermoelectric generator is used for waste heat recovery, conversion efficiency is quite difficult to be measured. This is due to time delay between the change of temperature profile in the thermoelectric generator and the change of heat medium temperature. Decrease of output current is desired to enlarge output because decrease of current decreases Peltier heat and improves efficiency of heat recovery. The experimental results indicate that current fluctuated by MPPT control causes loss of power output. We proposed the optimal control in which current is 10% smaller than one of MPPT control and evaluated it experimentally. We call this control scheme MEPT control. In this evaluation 500 W class thermoelectric generator, latent heat accumulator and the test facilities included 30 kW electric heater are utilized. Experimental result shows MEPT control exceeds MPPT in total electricity recovered from heat accumulator.
出处 《Journal of Power and Energy Engineering》 2017年第4期1-8,共8页 电力能源(英文)
关键词 THERMOELECTRIC GENERATOR Heat ACCUMULATOR MPPT MEPT Thermoelectric Generator Heat Accumulator MPPT MEPT
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部