期刊文献+

Impacts of Water-Tree Fault on Ferroresonance in Underground Cables

Impacts of Water-Tree Fault on Ferroresonance in Underground Cables
下载PDF
导出
摘要 Nowadays, more and more electrical power is being distributed to customers by underground cables rather than overhead transmission lines due to their advantage of providing better protection in inclement weather. They also have significantly reduced electromagnetic field emission because of their copper shielding. But underground cables have larger capacitance than transmission lines per unit. Thus, ferroresonance is more likely to occur in distribution systems using underground cables. Moreover, soil humidity at a depth of one meter remains 100 percent for most of the year, a factor that risks the occurrence of water tree (WT) in cables. Consequently, both ferroresonance and WT are prone to occur in underground cable systems. The objective of this paper is to determine the relationship between ferroresonance and water tree. A test system was designed to simulate and analyze ferroresonance in a cable system caused by single-phase switch and water tree. Eight scenarios of water tree were compared in the simulation. There sponses of ferroresonance are presented in this paper and two common patterns are observed from the simulation results. Nowadays, more and more electrical power is being distributed to customers by underground cables rather than overhead transmission lines due to their advantage of providing better protection in inclement weather. They also have significantly reduced electromagnetic field emission because of their copper shielding. But underground cables have larger capacitance than transmission lines per unit. Thus, ferroresonance is more likely to occur in distribution systems using underground cables. Moreover, soil humidity at a depth of one meter remains 100 percent for most of the year, a factor that risks the occurrence of water tree (WT) in cables. Consequently, both ferroresonance and WT are prone to occur in underground cable systems. The objective of this paper is to determine the relationship between ferroresonance and water tree. A test system was designed to simulate and analyze ferroresonance in a cable system caused by single-phase switch and water tree. Eight scenarios of water tree were compared in the simulation. There sponses of ferroresonance are presented in this paper and two common patterns are observed from the simulation results.
出处 《Journal of Power and Energy Engineering》 2017年第12期75-86,共12页 电力能源(英文)
关键词 FERRORESONANCE WATER TREE PSCAD COMSOL OVERVOLTAGE Ferroresonance Water Tree PSCAD COMSOL Overvoltage
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部