期刊文献+

Simulating the Stress-Strain Response of Building under Oscillating Wind Conditions

Simulating the Stress-Strain Response of Building under Oscillating Wind Conditions
下载PDF
导出
摘要 Wind load is one of the main lateral control loads that need to be considered in the design of high-rise building structures. It is also of great engineering significance to study the influence of static wind load or time-varying wind load on the dynamic response of structures. In this paper, a high-rise building with a rectangular section (46.8 m × 27 m × 33 m) is simulated based on Ansys18.0 APDL software. The real situation of its response under no lateral wind load and different fluctuating wind load conditions is simulated and the stress and strain response of the building under steady-state and time-varying wind load is given. The results show that the upper strain of the structure under wind load is about 1/1000 of the bottom strain, and the strain of the structure shows obvious accumulation from the top to the bottom, that is, the bottom strain of the building will be higher than the top strain. The influence of time-varying wind load on building structure is related to the loading position of wind load on the structure. The results provide a basis for the structural wind resistance design of this type of building. Wind load is one of the main lateral control loads that need to be considered in the design of high-rise building structures. It is also of great engineering significance to study the influence of static wind load or time-varying wind load on the dynamic response of structures. In this paper, a high-rise building with a rectangular section (46.8 m × 27 m × 33 m) is simulated based on Ansys18.0 APDL software. The real situation of its response under no lateral wind load and different fluctuating wind load conditions is simulated and the stress and strain response of the building under steady-state and time-varying wind load is given. The results show that the upper strain of the structure under wind load is about 1/1000 of the bottom strain, and the strain of the structure shows obvious accumulation from the top to the bottom, that is, the bottom strain of the building will be higher than the top strain. The influence of time-varying wind load on building structure is related to the loading position of wind load on the structure. The results provide a basis for the structural wind resistance design of this type of building.
作者 Miao Liu Zijie Qu Miao Liu;Zijie Qu(School of Civil Engineering and Architecture, Wuhan Institute of Technology, Wuhan, China;California Institute of Technology, Pasadena, California, USA)
出处 《Open Journal of Civil Engineering》 2023年第3期443-453,共11页 土木工程期刊(英文)
关键词 Multistory Framework Cumulative Strain Wind Load Analysis Finite Element Tool Multistory Framework Cumulative Strain Wind Load Analysis Finite Element Tool
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部