摘要 This paper describes two case studies: 1) a cogeneration system of a hospital and 2) a heat pump system installed in an aquarium that uses seawater for latent heat storage. The cogeneration system is an autonomous system that combines the generation of electrical, heating, and cooling energies in a hospital. Cogeneration systems can provide simultaneous heating and cooling. No technical obstacles were identified for implementing the cogeneration system. The average ratio between electric and thermal loads in the hospital was suitable for the cogeneration system operation. An analysis performed for a non-optimized cogeneration system predicted large potential for energy savings and CO2 reduction. The heat pump system using a low-temperature unutilized heat source is introduced on a heat source load responsive heat pump system, which combines a load variation responsive heat pump utilizing seawater with a latent heat-storage system (ice and water slurry), using nighttime electric power to level the electric power load. The experimental coefficient of performance (COP) of the proposed heat exchanger from the heat pump system, assisted by using seawater as latent heat storage for cooling, is discussed in detail. This paper describes two case studies: 1) a cogeneration system of a hospital and 2) a heat pump system installed in an aquarium that uses seawater for latent heat storage. The cogeneration system is an autonomous system that combines the generation of electrical, heating, and cooling energies in a hospital. Cogeneration systems can provide simultaneous heating and cooling. No technical obstacles were identified for implementing the cogeneration system. The average ratio between electric and thermal loads in the hospital was suitable for the cogeneration system operation. An analysis performed for a non-optimized cogeneration system predicted large potential for energy savings and CO2 reduction. The heat pump system using a low-temperature unutilized heat source is introduced on a heat source load responsive heat pump system, which combines a load variation responsive heat pump utilizing seawater with a latent heat-storage system (ice and water slurry), using nighttime electric power to level the electric power load. The experimental coefficient of performance (COP) of the proposed heat exchanger from the heat pump system, assisted by using seawater as latent heat storage for cooling, is discussed in detail.
出处 《Open Journal of Energy Efficiency》 2013年第2期107-120,共14页 能源效率(英文)
关键词 COGENERATION SYSTEM Heat Pump SYSTEM Energy Saving CO2 REDUCTION Hospital AQUARIUM Cogeneration System Heat Pump System Energy Saving CO2 Reduction Hospital Aquarium
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部