期刊文献+

Energy and Emission Reduction Potential for Bank ATM Units in India

Energy and Emission Reduction Potential for Bank ATM Units in India
下载PDF
导出
摘要 With the growing economy of India, banking sector growth has led to installation of thousands of Automatic Teller Machines (ATMs) throughout the country. ATMs provide 24 × 7 services as well as operate at low-temperature ranges of cooling, hence have high operating energy costs. Insulating an ATM’s envelope is not a prevalent technique in India. In the present study, an effort has been made to determine the optimum insulation thickness for three different insulation materials for the typical ATM envelope in four different climatic zones of India. Life cycle savings and payback periods for various insulation materials are also evaluated. Further, these optimally insulated ATM envelopes can be integrated with grid connected rooftop solar PV systems. The energy saving and emissions reduction potential due to these two interventions have been estimated on the national basis. Altogether in the four selected climate zones, energy saving of 17% - 30% provides the annual economic benefit of Indian National Rupees (Rs.) 3570 million with annual carbon reduction potential of about 0.60 million tCO<sub>2</sub>. From this study, it is observed that properly insulated ATMs integrated with rooftop solar PV systems, can significantly reduce the energy costs as well as carbon emissions in India’s context. With the growing economy of India, banking sector growth has led to installation of thousands of Automatic Teller Machines (ATMs) throughout the country. ATMs provide 24 × 7 services as well as operate at low-temperature ranges of cooling, hence have high operating energy costs. Insulating an ATM’s envelope is not a prevalent technique in India. In the present study, an effort has been made to determine the optimum insulation thickness for three different insulation materials for the typical ATM envelope in four different climatic zones of India. Life cycle savings and payback periods for various insulation materials are also evaluated. Further, these optimally insulated ATM envelopes can be integrated with grid connected rooftop solar PV systems. The energy saving and emissions reduction potential due to these two interventions have been estimated on the national basis. Altogether in the four selected climate zones, energy saving of 17% - 30% provides the annual economic benefit of Indian National Rupees (Rs.) 3570 million with annual carbon reduction potential of about 0.60 million tCO<sub>2</sub>. From this study, it is observed that properly insulated ATMs integrated with rooftop solar PV systems, can significantly reduce the energy costs as well as carbon emissions in India’s context.
作者 Hemant Kumar Singh Ravi Prakash Karunesh Kumar Shukla Hemant Kumar Singh;Ravi Prakash;Karunesh Kumar Shukla(Department of Mechanical Engineering, Motilal Nehru National Institute of Technology, Allahabad, India;Department of Applied Mechanics, Motilal Nehru National Institute of Technology, Allahabad, India)
出处 《Open Journal of Energy Efficiency》 2016年第4期107-120,共15页 能源效率(英文)
关键词 Life Cycle Cost Optimum Insulation Thickness Life Cycle Saving Solar PV Payback Period Carbon Emissions Life Cycle Cost Optimum Insulation Thickness Life Cycle Saving Solar PV Payback Period Carbon Emissions
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部