期刊文献+

Characterisation of Raw Sewage and Performance Evaluation of Al-Diwaniyah Sewage Treatment Work, Iraq

Characterisation of Raw Sewage and Performance Evaluation of Al-Diwaniyah Sewage Treatment Work, Iraq
下载PDF
导出
摘要 These days, water and wastewater treatment are one of the most important issues regarding to the human health. Wastewaters are one of the most environmental pollutants and a wide range of adverse effects linked to the effect of untreated wastewaters or wastewaters that treat improperly. The aim of this present study was to evaluate performance of the wastewater treatment plant at Al-Diwaniyah City according to the national standards. Therefore, data of the most common parameters (PH, BOD<sub>5</sub>, COD, TSS, PO<sub>4</sub>, NO<sub>3</sub>, Cl, and Oil and Grease) were collected from the wastewater treatment plant. The study revealed that the wastewater treatment plant was receiving medium to strong influent with a BOD<sub>5</sub>/COD ratio of between (0.4 - 0.7). Regression analysis was achieved to approximate the influent of BOD<sub>5</sub> and TSS. While the effluent quality was exceeded the Iraq standards for disposing treated wastewater to the water bodies with a fluctuation in the ratio of BOD5to COD as a consequence of the operational problems. Therefore, these results would be of help to planners and policy makers in the City to combat such this problem and to take the necessary actions to reduce the impact of these pollutants. These days, water and wastewater treatment are one of the most important issues regarding to the human health. Wastewaters are one of the most environmental pollutants and a wide range of adverse effects linked to the effect of untreated wastewaters or wastewaters that treat improperly. The aim of this present study was to evaluate performance of the wastewater treatment plant at Al-Diwaniyah City according to the national standards. Therefore, data of the most common parameters (PH, BOD<sub>5</sub>, COD, TSS, PO<sub>4</sub>, NO<sub>3</sub>, Cl, and Oil and Grease) were collected from the wastewater treatment plant. The study revealed that the wastewater treatment plant was receiving medium to strong influent with a BOD<sub>5</sub>/COD ratio of between (0.4 - 0.7). Regression analysis was achieved to approximate the influent of BOD<sub>5</sub> and TSS. While the effluent quality was exceeded the Iraq standards for disposing treated wastewater to the water bodies with a fluctuation in the ratio of BOD5to COD as a consequence of the operational problems. Therefore, these results would be of help to planners and policy makers in the City to combat such this problem and to take the necessary actions to reduce the impact of these pollutants.
作者 Hussein Janna Hussein Janna(Civil Engineering Department, Al-Qadisiyah University, Al-Diwaniyah, Iraq)
出处 《World Journal of Engineering and Technology》 2016年第2期296-304,共9页 世界工程和技术(英文)
关键词 Biochemical Oxygen Demand Total Suspended Solids Al-Diwaniyah Sewage Treatment Works Activated Sludge Process Biochemical Oxygen Demand Total Suspended Solids Al-Diwaniyah Sewage Treatment Works Activated Sludge Process
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部