期刊文献+

Assessment of Modeling Collimator Designs for Gamma-Ray Transmission of Uranium Oxide Spectrometry Using HPGe Detectors

Assessment of Modeling Collimator Designs for Gamma-Ray Transmission of Uranium Oxide Spectrometry Using HPGe Detectors
下载PDF
导出
摘要 Many scientific domains use gamma-ray spectrometry, but non-destructive gamma scanning and gamma emission tomography of radioactive fuel in particular. In the experimental setting, a collimator is frequently employed to focus on a particular location of interest in the fuel. Predictive models for the transmitted gamma-ray intensity through the collimator are required for both the optimization of instrument design and the planning of measurement campaigns. Gamma-ray transport accuracy is frequently predicted using Monte Carlo radiation transport methods, but using these tools in low-efficiency experimental setups is challenging due to the lengthy computation times needed. This study focused on the full-energy peak intensity that was transmitted through several collimator designs, including rectangle and cylinder. The rate of photons arriving at a detector on the other side of the collimator was calculated for anisotropic source of SNM (U<sub>3</sub>O<sub>8</sub>). Some geometrical assumptions that depended on the source-to-collimator distance and collimator dimensions (length, radius or length, height, and width) were applied to achieve precise findings. Many scientific domains use gamma-ray spectrometry, but non-destructive gamma scanning and gamma emission tomography of radioactive fuel in particular. In the experimental setting, a collimator is frequently employed to focus on a particular location of interest in the fuel. Predictive models for the transmitted gamma-ray intensity through the collimator are required for both the optimization of instrument design and the planning of measurement campaigns. Gamma-ray transport accuracy is frequently predicted using Monte Carlo radiation transport methods, but using these tools in low-efficiency experimental setups is challenging due to the lengthy computation times needed. This study focused on the full-energy peak intensity that was transmitted through several collimator designs, including rectangle and cylinder. The rate of photons arriving at a detector on the other side of the collimator was calculated for anisotropic source of SNM (U<sub>3</sub>O<sub>8</sub>). Some geometrical assumptions that depended on the source-to-collimator distance and collimator dimensions (length, radius or length, height, and width) were applied to achieve precise findings.
作者 Rasha Ali El-Tayebany Hekmat Elbegawy Rasha Ali El-Tayebany;Hekmat Elbegawy(Nuclear and Radiological Safety Research Center, Egyptian Atomic Energy Authority, Cairo, Egypt)
出处 《World Journal of Engineering and Technology》 2023年第4期663-671,共9页 世界工程和技术(英文)
关键词 Monte Carlo High Purity Germanium (HPGe) COLLIMATOR URANIUM Monte Carlo High Purity Germanium (HPGe) Collimator Uranium
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部