期刊文献+

A Simple Sample Processing Protocol and Multiplex PCR for Direct Detection of MRSA from Uncultured Clinical Samples—A Pilot Study

A Simple Sample Processing Protocol and Multiplex PCR for Direct Detection of MRSA from Uncultured Clinical Samples—A Pilot Study
下载PDF
导出
摘要 Phenotypic tests have limited discrimatory power to identify closely related members of genus Staphylococcus and particularly for identification of S. aureus. 157 isolates of S. aureus obtained from different clinical specimens were included in our study. To present a demonstration of our method’s sensitivity and ability to correctly detect S. aureus from uncultured clinical specimen, 30 known S. aureus positive but leftover uncultured clinical specimens from clinical microbiology laboratory were processed by our protocol and analyzed. All the 30 clinical specimens were confirmed as S. aureus among which 26 specimen were identified as MRSA and the remaining 4 as MSSA. These 30 clinical specimens used in the study showed 100% correlation with coagulase test and Cefoxitin disc diffusion method. Though commercial molecular diagnostic kits are available for detecting MRSA from swabs, this is probably the first time that multiplex PCR is being demonstrated directly on a variety of uncultured clinical specimens. Phenotypic tests have limited discrimatory power to identify closely related members of genus Staphylococcus and particularly for identification of S. aureus. 157 isolates of S. aureus obtained from different clinical specimens were included in our study. To present a demonstration of our method’s sensitivity and ability to correctly detect S. aureus from uncultured clinical specimen, 30 known S. aureus positive but leftover uncultured clinical specimens from clinical microbiology laboratory were processed by our protocol and analyzed. All the 30 clinical specimens were confirmed as S. aureus among which 26 specimen were identified as MRSA and the remaining 4 as MSSA. These 30 clinical specimens used in the study showed 100% correlation with coagulase test and Cefoxitin disc diffusion method. Though commercial molecular diagnostic kits are available for detecting MRSA from swabs, this is probably the first time that multiplex PCR is being demonstrated directly on a variety of uncultured clinical specimens.
出处 《Advances in Infectious Diseases》 2019年第1期25-38,共14页 传染病进展(英文)
关键词 MECA nuc Multiplex PCR S. AUREUS mecA nuc Multiplex PCR S. aureus
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部