摘要
1) Background: Osteoarthritis (OA) is defined as a degenerative joint disease that mainly affects the bone. This study aims to evaluate the effect of low-intensity continuous ultrasound (LICUS) treatment on the knee of osteoarthritis patients through home-based intervention using the LICUS medical device. 2) Methods: The clinical trials were designed in a single-arm, open-label, and intervention study. Thirty-five participants, including those who dropped out (12%), were screened and enrolled. The patients received LICUS (1.1 MHz, 1.5 W/cm2, collimated beams) on the knee by the instructions of the investigator at home (5 min/session, 3 times/day, for four-weeks). Outcome measures were assessed using the Visual Analog Scale (VAS) as a primary endpoint and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) as a secondary endpoint to evaluate pain relief and functional recovery of the knee between pre-treatment (baseline) and post-treatment (four-weeks). 3) Results: Knee pain scores measured using the VAS and WOMAC indices were significantly reduced after a four-week treatment with LICUS compared to baseline. Knee stiffness and functional capacity were significantly reduced after the LICUS application. In addition, there were no reports of adverse effects during the study period. 4) Conclusion: Long-term and home-based application of LICUS can be recommended as an alternative option for the treatment of OA patients, as evidenced by the effect of pain relief and knee function recovery.
1) Background: Osteoarthritis (OA) is defined as a degenerative joint disease that mainly affects the bone. This study aims to evaluate the effect of low-intensity continuous ultrasound (LICUS) treatment on the knee of osteoarthritis patients through home-based intervention using the LICUS medical device. 2) Methods: The clinical trials were designed in a single-arm, open-label, and intervention study. Thirty-five participants, including those who dropped out (12%), were screened and enrolled. The patients received LICUS (1.1 MHz, 1.5 W/cm2, collimated beams) on the knee by the instructions of the investigator at home (5 min/session, 3 times/day, for four-weeks). Outcome measures were assessed using the Visual Analog Scale (VAS) as a primary endpoint and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) as a secondary endpoint to evaluate pain relief and functional recovery of the knee between pre-treatment (baseline) and post-treatment (four-weeks). 3) Results: Knee pain scores measured using the VAS and WOMAC indices were significantly reduced after a four-week treatment with LICUS compared to baseline. Knee stiffness and functional capacity were significantly reduced after the LICUS application. In addition, there were no reports of adverse effects during the study period. 4) Conclusion: Long-term and home-based application of LICUS can be recommended as an alternative option for the treatment of OA patients, as evidenced by the effect of pain relief and knee function recovery.
作者
Md. Habibur Rahman
Yeon-Gyu Jang
Johny Bajgai
Subham Sharma
Kchorng Vira
Abdul-Nasir Sofian
Seong Hoon Goh
Yundeok Kim
Cheol-Su Kim
Doo-Sup Kim
Kyu-Jae Lee
Md. Habibur Rahman;Yeon-Gyu Jang;Johny Bajgai;Subham Sharma;Kchorng Vira;Abdul-Nasir Sofian;Seong Hoon Goh;Yundeok Kim;Cheol-Su Kim;Doo-Sup Kim;Kyu-Jae Lee(Department of Convergence Medicine, Wonju College of Medicine, Yonsei University, Wonju, Republic of Korea;Department of Neurosurgery, Wonju Severance Christian Hospital, Wonju College of Medicine, Yonsei University, Wonju, Republic of Korea;Department of Global Medical Science, Wonju College of Medicine, Yonsei University, Wonju, Republic of Korea;Department of Internal Medicine, Division of Hematology-Oncology, Wonju Severance Christian Hospital, Wonju, Republic of Korea;Department of Orthopaedic Surgery, Wonju College of Medicine, Yonsei University, Wonju, Republic of Korea)