Evaluation of Nasal and Temporal Anterior Chamber Angle with Four Different Techniques

下载PDF
导出
摘要 Background: Anterior chamber angle (ACA) can be measured by many different techniques. In order for a technique to be a part of the routine eye examination, it has to be quick and easy in good agreement with gonioscopy both nasally and temporally. Aim: To investigate variation in ACA measurement between gonioscopy, van Herick technique, anterior segment optical coherence tomography (AS-OCT) and Sirius Scheimpflug-Camera both nasally and temporally. Method: The ACA of 50 eyes of 25 healthy subjects was measured with gonioscopy, van Herick technique, AS-OCT and Sirius Scheimpflug-Camera. The angle was measured both nasally and temporally. Results: No statistically significant difference could be found between gonioscopy, van Herick technique and AS-OCT either nasally or temporally. The Sirius Scheimpflug-Camera on the other hand showed statistically significant difference to gonioscopy (p < 0.0001) both nasally (p = 0.03, p = 0.001, p < 0.0001) and temporally (p = 0.0002, p = 0.001, p Conclusion: This study showed good agreement between three of the four techniques. ACA measurements obtained by the Sirius Scheimpflug-Camera should therefore not be considered interchangeable with those obtained by the remaining three methods. Background: Anterior chamber angle (ACA) can be measured by many different techniques. In order for a technique to be a part of the routine eye examination, it has to be quick and easy in good agreement with gonioscopy both nasally and temporally. Aim: To investigate variation in ACA measurement between gonioscopy, van Herick technique, anterior segment optical coherence tomography (AS-OCT) and Sirius Scheimpflug-Camera both nasally and temporally. Method: The ACA of 50 eyes of 25 healthy subjects was measured with gonioscopy, van Herick technique, AS-OCT and Sirius Scheimpflug-Camera. The angle was measured both nasally and temporally. Results: No statistically significant difference could be found between gonioscopy, van Herick technique and AS-OCT either nasally or temporally. The Sirius Scheimpflug-Camera on the other hand showed statistically significant difference to gonioscopy (p < 0.0001) both nasally (p = 0.03, p = 0.001, p < 0.0001) and temporally (p = 0.0002, p = 0.001, p Conclusion: This study showed good agreement between three of the four techniques. ACA measurements obtained by the Sirius Scheimpflug-Camera should therefore not be considered interchangeable with those obtained by the remaining three methods.
机构地区 Unit of Optometry
出处 《International Journal of Clinical Medicine》 2013年第12期548-555,共8页 临床医学国际期刊(英文)
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部