期刊文献+

Dosimetric Comparison of Fixed and Flexible Geometry ICRT Applicators in Patients Treated for Carcinoma Cervix

Dosimetric Comparison of Fixed and Flexible Geometry ICRT Applicators in Patients Treated for Carcinoma Cervix
下载PDF
导出
摘要 In intracavitary radiotherapy (ICRT) for cancer cervix, applicator geometry has the potential to impact the doses to organs at risk (OARs) and the coverage of the target volume. At our centre two Varian made Fletcher-style applicator sets, namely defined (fixed) geometry and flexible geometry, are used for ICRT. In the present work, the two types of applicators were compared dosimetrically as per the recommendations of the International Commission on Radiation Units and Measurements (ICRU-38) while delivering high dose rate brachytherapy. Twenty four patients who underwent ICRT were considered for this study. Radiographic method was used for treatment planning on Abacus planning system. ICRU-38 recommended parameters were estimated and compared. Flexible geometry applicator showed 8.8% and 16% higher bladder and rectum point doses as compared to the fixed geometry one but the difference was statistically not significant. The thickness of the pear-shaped isodose volume was larger for the flexible geometry implant also indicating towards higher doses to OARs. The higher bladder and rectum point doses in the case of flexible applicator will need to be validated by a larger data set. In intracavitary radiotherapy (ICRT) for cancer cervix, applicator geometry has the potential to impact the doses to organs at risk (OARs) and the coverage of the target volume. At our centre two Varian made Fletcher-style applicator sets, namely defined (fixed) geometry and flexible geometry, are used for ICRT. In the present work, the two types of applicators were compared dosimetrically as per the recommendations of the International Commission on Radiation Units and Measurements (ICRU-38) while delivering high dose rate brachytherapy. Twenty four patients who underwent ICRT were considered for this study. Radiographic method was used for treatment planning on Abacus planning system. ICRU-38 recommended parameters were estimated and compared. Flexible geometry applicator showed 8.8% and 16% higher bladder and rectum point doses as compared to the fixed geometry one but the difference was statistically not significant. The thickness of the pear-shaped isodose volume was larger for the flexible geometry implant also indicating towards higher doses to OARs. The higher bladder and rectum point doses in the case of flexible applicator will need to be validated by a larger data set.
出处 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2015年第1期1-6,共6页 医学物理学、临床工程、放射肿瘤学(英文)
关键词 CARCINOMA CERVIX Intracavitary RADIOTHERAPY APPLICATOR GEOMETRY DOSIMETRY Carcinoma Cervix Intracavitary Radiotherapy Applicator Geometry Dosimetry
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部