期刊文献+

Influence of Distinct Radiotherapy Techniques to Induce Second Cancer Risks in Left Breast Cancer

Influence of Distinct Radiotherapy Techniques to Induce Second Cancer Risks in Left Breast Cancer
下载PDF
导出
摘要 Influence of distinct radiotherapy techniques to induce second cancer risks in left breast cancer. Material and methods: Ten female patients with intact left breast cancer. Two treatment plans for each patient: 1) two tangential beams 3D-Conformal radiotherapy, 2) intensity-modulated radiotherapy (IMRT) plan. Estimation of second cancer risk from Organ equivalent dose models (OEDs) in three dose-response model for organs at risk in left breast cases. Results: The P-value for OED models in 3D-IMRT for left lung, both lung, heart, right lung, right breast, thyroid, liver and spinal cord in linear dose model was 0.016, 0.005, 0.019, 3.95E-06, 5.79E-07, 0.003, 1.78E-10 and 0.000206475 respectively, for linear exponential dose model 0.0577, 0.024, 0.031, 3.40E-06, 3.28E-07, 0.003, 2.01E-10 and 0.000120072 respectively and in plateau dose model 0.088, 0.042, 0.039, 3.18E-06, 2.53E-07, 0.003, 2.27E-10 and 9.00535E-05 respectively. Conclusion: organ equivalent dose models for organs at risk increasing in IMRT than tangential beams. Influence of distinct radiotherapy techniques to induce second cancer risks in left breast cancer. Material and methods: Ten female patients with intact left breast cancer. Two treatment plans for each patient: 1) two tangential beams 3D-Conformal radiotherapy, 2) intensity-modulated radiotherapy (IMRT) plan. Estimation of second cancer risk from Organ equivalent dose models (OEDs) in three dose-response model for organs at risk in left breast cases. Results: The P-value for OED models in 3D-IMRT for left lung, both lung, heart, right lung, right breast, thyroid, liver and spinal cord in linear dose model was 0.016, 0.005, 0.019, 3.95E-06, 5.79E-07, 0.003, 1.78E-10 and 0.000206475 respectively, for linear exponential dose model 0.0577, 0.024, 0.031, 3.40E-06, 3.28E-07, 0.003, 2.01E-10 and 0.000120072 respectively and in plateau dose model 0.088, 0.042, 0.039, 3.18E-06, 2.53E-07, 0.003, 2.27E-10 and 9.00535E-05 respectively. Conclusion: organ equivalent dose models for organs at risk increasing in IMRT than tangential beams.
出处 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2018年第2期193-202,共10页 医学物理学、临床工程、放射肿瘤学(英文)
关键词 Breast CANCER Second CANCER RISKS 3DCRT 7 Field IMRT Breast Cancer Second Cancer Risks 3DCRT 7 Field IMRT
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部