期刊文献+

Considerations and Experience in the Treatment of Lung Cancer with VMAT SBRT + DIBH in Arms-Down Position

Considerations and Experience in the Treatment of Lung Cancer with VMAT SBRT + DIBH in Arms-Down Position
下载PDF
导出
摘要 <div style="text-align:justify;"> The arms-up position is the most common treatment position adopted for lung cancer patients treated with radiation therapy. However, many elderly or frail patients have shoulder problems and cannot tolerate such an overstretched position for an extended period. Therefore, the arms-down position becomes the only alternative for this group of patients during radiation therapy. Even though the arms-down position is not ideal, it does provide a stable and comfortable patient immobilization position for radiation treatments that require a longer delivery time, such as stereotactic body radiation therapy (SBRT). In this study, we designed a protocol to treat lung cancer patients with VMAT stereotactic body radiation therapy (VMAT SBRT) and deep inspiration breath-hold (DIBH) in the arms-down position. Our initial clinical experience with this protocol indicates that it is reliable for patient immobilization and accurate in delivered dosimetry. </div> <div style="text-align:justify;"> The arms-up position is the most common treatment position adopted for lung cancer patients treated with radiation therapy. However, many elderly or frail patients have shoulder problems and cannot tolerate such an overstretched position for an extended period. Therefore, the arms-down position becomes the only alternative for this group of patients during radiation therapy. Even though the arms-down position is not ideal, it does provide a stable and comfortable patient immobilization position for radiation treatments that require a longer delivery time, such as stereotactic body radiation therapy (SBRT). In this study, we designed a protocol to treat lung cancer patients with VMAT stereotactic body radiation therapy (VMAT SBRT) and deep inspiration breath-hold (DIBH) in the arms-down position. Our initial clinical experience with this protocol indicates that it is reliable for patient immobilization and accurate in delivered dosimetry. </div>
作者 Yulin Song Boris Mueller Kenneth Dow Ziad Saleh Xiaoli Tang Melissa Zinovoy Daphna Gelblum Borys Mychalczak Yulin Song;Boris Mueller;Kenneth Dow;Ziad Saleh;Xiaoli Tang;Melissa Zinovoy;Daphna Gelblum;Borys Mychalczak(Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, USA;Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, USA)
出处 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2021年第2期69-80,共12页 医学物理学、临床工程、放射肿瘤学(英文)
关键词 Lung Cancer VMAT SBRT DIBH Arms-Down Position Lung Cancer VMAT SBRT DIBH Arms-Down Position
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部