期刊文献+

Electrochemical Biosensor for Detection of Staphylococcus aureus Based on Nucleic Acid Aptamers

Electrochemical Biosensor for Detection of Staphylococcus aureus Based on Nucleic Acid Aptamers
下载PDF
导出
摘要 Staphylococcus aureus is a gram-staining positive cocci bacillus baterium and also one of the foodborne pathogens, which is a serious potential hazard to human health and food safety. We constructed an electrochemical biosensor for the detection of S. aureus based on nucleic acid aptamers to achieve highly specific detection of S. aureus. The detection of S. aureus was realized by using Aptamer (Apt) to capture S. aureus, which resulted in a change in the spatial conformation of Apt and a decrease in the electrochemical signal. Under the optimized experimental conditions, the detected electrochemical signals were positively correlated with the concentration of S. aureus with a linear range of 1 × 10<sup>1</sup> - 1 × 10<sup>5</sup> CFU/mL, a detection limit of 4.76 CFU/mL, and an experimental recovery of 97.43% - 99.37%. Therefore, we successfully constructed an electrochemical biosensor for the specific detection of S. aureus, which has the advantages of high specificity, sensitive detection and convenient operation. Staphylococcus aureus is a gram-staining positive cocci bacillus baterium and also one of the foodborne pathogens, which is a serious potential hazard to human health and food safety. We constructed an electrochemical biosensor for the detection of S. aureus based on nucleic acid aptamers to achieve highly specific detection of S. aureus. The detection of S. aureus was realized by using Aptamer (Apt) to capture S. aureus, which resulted in a change in the spatial conformation of Apt and a decrease in the electrochemical signal. Under the optimized experimental conditions, the detected electrochemical signals were positively correlated with the concentration of S. aureus with a linear range of 1 × 10<sup>1</sup> - 1 × 10<sup>5</sup> CFU/mL, a detection limit of 4.76 CFU/mL, and an experimental recovery of 97.43% - 99.37%. Therefore, we successfully constructed an electrochemical biosensor for the specific detection of S. aureus, which has the advantages of high specificity, sensitive detection and convenient operation.
作者 Xuejun Liang Wenhui Li Xuejun Liang;Wenhui Li(School of Basic Medical, Youjiang Medical University for Nationalities, Baise, China;School of Pharmacy, Wenzhou Medical University, Wenzhou, China)
出处 《Journal of Biosciences and Medicines》 2023年第11期133-140,共8页 生物科学与医学(英文)
关键词 S. aureus Nucleic Acid Aptamer ELECTROCHEMISTRY S. aureus Nucleic Acid Aptamer Electrochemistry
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部