期刊文献+

Depressed Acne Scars—Effective, Minimal Downtime Treatment with a Novel Smooth Motion Non-Insulated Microneedle Radiofrequency Technology 被引量:5

Depressed Acne Scars—Effective, Minimal Downtime Treatment with a Novel Smooth Motion Non-Insulated Microneedle Radiofrequency Technology
下载PDF
导出
摘要 Background: The microneedle fractional RF handpiece used in our study (Intensif Handpiece, EndyMed Medical, Caesarea, Israel) is a novel handpiece that uses a tip with 25 non-insulated, gold plated microneedle electrodes. The needles are inserted into the skin by a specially designed electronically controlled, smooth motion motor minimizing patient discomfort. RF emission delivered over the whole dermal portion of the needle allows effective coagulation resulting in minimal or no bleeding, together with bulk volumetric heating. Study Design/Materials and Methods: The study included 20 patients, treated for depressed acne scars using the IntensifTM?Microneedles handpiece (EndyMed PRO Platform System, EndyMed Medical, Caesarea, Israel). The degree of clinical improvement was assessed by the global aesthetic improvement scale (GAIS) and subjects satisfaction by post treatment questionnaires. Results: The number of treatments per patient varied between 1 and 6 (average 3.3 treatments per patient). Eleven patients (55%) reported none to minimal pain, six (30%) moderate discomfort and only three (15%) reported significant pain. Objective evaluation of the improvement by a board certified dermatologist showed improvement in 95% of patients. 25% showed excellent improvement, 50% experienced good improvement, and the 20% showed minimal improvement. One patient showed no improvement. Conclusions: The presented results show that the tested electronically controlled motorized insertion, non-insulated microneedle treatment technology provides a minimal discomfort, minimal downtime, effective and safe treatment for depressed acne scars. Background: The microneedle fractional RF handpiece used in our study (Intensif Handpiece, EndyMed Medical, Caesarea, Israel) is a novel handpiece that uses a tip with 25 non-insulated, gold plated microneedle electrodes. The needles are inserted into the skin by a specially designed electronically controlled, smooth motion motor minimizing patient discomfort. RF emission delivered over the whole dermal portion of the needle allows effective coagulation resulting in minimal or no bleeding, together with bulk volumetric heating. Study Design/Materials and Methods: The study included 20 patients, treated for depressed acne scars using the IntensifTM?Microneedles handpiece (EndyMed PRO Platform System, EndyMed Medical, Caesarea, Israel). The degree of clinical improvement was assessed by the global aesthetic improvement scale (GAIS) and subjects satisfaction by post treatment questionnaires. Results: The number of treatments per patient varied between 1 and 6 (average 3.3 treatments per patient). Eleven patients (55%) reported none to minimal pain, six (30%) moderate discomfort and only three (15%) reported significant pain. Objective evaluation of the improvement by a board certified dermatologist showed improvement in 95% of patients. 25% showed excellent improvement, 50% experienced good improvement, and the 20% showed minimal improvement. One patient showed no improvement. Conclusions: The presented results show that the tested electronically controlled motorized insertion, non-insulated microneedle treatment technology provides a minimal discomfort, minimal downtime, effective and safe treatment for depressed acne scars.
出处 《Journal of Cosmetics, Dermatological Sciences and Applications》 2014年第3期212-218,共7页 化妆品、皮肤病及应用期刊(英文)
关键词 MICRONEEDLES Radio-Frequency Acne SCARS RF Multisource Fractional Lasers Non-Insulated Microneedles Radio-Frequency Acne Scars RF Multisource Fractional Lasers Non-Insulated
  • 相关文献

同被引文献48

引证文献5

二级引证文献39

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部