期刊文献+

Clinical Performances of Pure TB-Lamp Kit for <i>M. tuberculosis</i>Complex Detection in Sputum Samples

Clinical Performances of Pure TB-Lamp Kit for <i>M. tuberculosis</i>Complex Detection in Sputum Samples
下载PDF
导出
摘要 Tuberculosis represents a main concern for public health worldwide. In poor countries, the most prevalent method for bacteriological confirmation re- mains Smear Sputum Microscopy (SSM). This study objective was to assess clinical performances of Loop Mediated Isothermal Amplification for TB detection (Lamp-TB). Sputum of patients presenting symptoms consistent with tuberculosis were collected according to the National Tuberculosis Control Programme guidelines in Centre Antituberculeux de Yopougon. SSM after Ziehl-Neelsen staining and TB-Lamp were blindly performed with spot sputum specimen. Samples, transported at Institut Pasteur de Cote d’Ivoire were decontaminated according to N-acetyl-L-cystein (NALC) method. In Mycobacteria Growth Indicator Tube (MGIT), 500 μl of pellet were inoculated and incubated in MGIT 960 instrument. MPT64 antigen was detected on positive culture. Of 500 patients enrolled, 469 were included. Clinical isolates of M. tuberculosis Complex were detected for 157 (33.5%). Comparatively to culture, Sensitivity and Specificity of SSM were 86% (95% Confidence interval (CI): 81% - 91%) 96% (95%IC: 94% - 98%) respectively. TB-Lamp Sensitivity was 92% (95%CI: 88% - 96%), and Specificity 94% (95%CI: 91% - 97%). Positive Predictive Value of SSM and TB-Lamp was 91.8% and 88.8% respectively. Negative Predictive Value of TB-Lamp assay was 95.7% whereas this of SSM was 93.3%. Positive Likelihood Ratio was 15.3 for TB-Lamp and 21.5 for SSM 21.5 whereas negative Likelihood of TB-Lamp was lower than SSM. Active tuberculosis was detected in162/469 (34.5%) with TB-Lamp and 147 (31.3%) with SSM. TB-Lamp assay performances estimated from sputum samples may improve detection of active TB cases in routine. Tuberculosis represents a main concern for public health worldwide. In poor countries, the most prevalent method for bacteriological confirmation re- mains Smear Sputum Microscopy (SSM). This study objective was to assess clinical performances of Loop Mediated Isothermal Amplification for TB detection (Lamp-TB). Sputum of patients presenting symptoms consistent with tuberculosis were collected according to the National Tuberculosis Control Programme guidelines in Centre Antituberculeux de Yopougon. SSM after Ziehl-Neelsen staining and TB-Lamp were blindly performed with spot sputum specimen. Samples, transported at Institut Pasteur de Cote d’Ivoire were decontaminated according to N-acetyl-L-cystein (NALC) method. In Mycobacteria Growth Indicator Tube (MGIT), 500 μl of pellet were inoculated and incubated in MGIT 960 instrument. MPT64 antigen was detected on positive culture. Of 500 patients enrolled, 469 were included. Clinical isolates of M. tuberculosis Complex were detected for 157 (33.5%). Comparatively to culture, Sensitivity and Specificity of SSM were 86% (95% Confidence interval (CI): 81% - 91%) 96% (95%IC: 94% - 98%) respectively. TB-Lamp Sensitivity was 92% (95%CI: 88% - 96%), and Specificity 94% (95%CI: 91% - 97%). Positive Predictive Value of SSM and TB-Lamp was 91.8% and 88.8% respectively. Negative Predictive Value of TB-Lamp assay was 95.7% whereas this of SSM was 93.3%. Positive Likelihood Ratio was 15.3 for TB-Lamp and 21.5 for SSM 21.5 whereas negative Likelihood of TB-Lamp was lower than SSM. Active tuberculosis was detected in162/469 (34.5%) with TB-Lamp and 147 (31.3%) with SSM. TB-Lamp assay performances estimated from sputum samples may improve detection of active TB cases in routine.
出处 《Journal of Tuberculosis Research》 2017年第2期129-138,共10页 结核病研究(英文)
关键词 TUBERCULOSIS Ziehl-Neelsen TB-Lamp Assay Tuberculosis Ziehl-Neelsen TB-Lamp Assay
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部