Markerless Respiratory Motion Tracking Using Single Depth Camera 被引量:1

Markerless Respiratory Motion Tracking Using Single Depth Camera
下载PDF
导出
摘要 The aim of this study is to propose a novel system that has an ability to detect intra-fractional motion during radiotherapy treatment in real-time using three-dimensional surface taken by a depth camera, Microsoft Kinect v1. Our approach introduces three new aspects for three-dimensional surface tracking in radiotherapy treatment. The first aspect is a new algorithm for noise reduction of depth values. Ueda’s algorithm was implemented and enabling a fast least square regression of depth values. The second aspect is an application for detection of patient’s motion at multiple points in thracoabdominal regions. The third aspect is an estimation of three-dimensional surface from multiple depth values. For evaluation of noise reduction by Ueda’s algorithm, two respiratory patterns are measured by the Kinect as well as a laser range meter. The resulting cross correlation coefficients between the laser range meter and the Kinect were 0.982 for abdominal respiration and 0.995 for breath holding. Moreover, the mean cross correlation coefficients between the signals of our system and the signals of Anzai with respect to participant’s respiratory motion were 0.90 for thoracic respiration and 0.93 for abdominal respiration, respectively. These results proved that the performance of the developed system was comparable to existing motion monitoring devices. Reconstruction of three-dimensional surface also enabled us to detect the irregular motion and breathing arrest by comparing the averaged depth with predefined threshold values. The aim of this study is to propose a novel system that has an ability to detect intra-fractional motion during radiotherapy treatment in real-time using three-dimensional surface taken by a depth camera, Microsoft Kinect v1. Our approach introduces three new aspects for three-dimensional surface tracking in radiotherapy treatment. The first aspect is a new algorithm for noise reduction of depth values. Ueda’s algorithm was implemented and enabling a fast least square regression of depth values. The second aspect is an application for detection of patient’s motion at multiple points in thracoabdominal regions. The third aspect is an estimation of three-dimensional surface from multiple depth values. For evaluation of noise reduction by Ueda’s algorithm, two respiratory patterns are measured by the Kinect as well as a laser range meter. The resulting cross correlation coefficients between the laser range meter and the Kinect were 0.982 for abdominal respiration and 0.995 for breath holding. Moreover, the mean cross correlation coefficients between the signals of our system and the signals of Anzai with respect to participant’s respiratory motion were 0.90 for thoracic respiration and 0.93 for abdominal respiration, respectively. These results proved that the performance of the developed system was comparable to existing motion monitoring devices. Reconstruction of three-dimensional surface also enabled us to detect the irregular motion and breathing arrest by comparing the averaged depth with predefined threshold values.
作者 Shinobu Kumagai Ryohei Uemura Toru Ishibashi Susumu Nakabayashi Norikazu Arai Takenori Kobayashi Jun’ichi Kotoku Shinobu Kumagai;Ryohei Uemura;Toru Ishibashi;Susumu Nakabayashi;Norikazu Arai;Takenori Kobayashi;Jun’ichi Kotoku(Graduate School of Medical Technology, Teikyo University, Tokyo, Japan;Central of Radiology, Teikyo University Hospital, Tokyo, Japan)
出处 《Open Journal of Medical Imaging》 2016年第1期20-31,共12页 医学影像期刊(英文)
关键词 Depth Camera Markerless Motion Tracking Intra-Fractional Motion Three-Dimensional Surface Depth Camera Markerless Motion Tracking Intra-Fractional Motion Three-Dimensional Surface
  • 相关文献

同被引文献5

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部