期刊文献+

Intra- and Inter-Observer Reproducibility of Ultrasound Measurements of Pelvic Inlet Diameter in Pregnant Women 被引量:1

Intra- and Inter-Observer Reproducibility of Ultrasound Measurements of Pelvic Inlet Diameter in Pregnant Women
下载PDF
导出
摘要 Objectives: To determine intra- and inter-observer reproducibility of the ultrasound measurement of pelvic inlet in the first trimester of pregnancy. Methods: Transabdominal pelvic ultrasound was performed to measure the pelvic inlet anteroposterior diameter using a 2D probe in twelve Chinese women having a singleton pregnancy. Scans were performed in the first trimester by three sonographers. The pelvic inlet anteroposterior diameter was defined as the distance between the anterior surfaces of the sacral promontory and the superior medial border of the pubic bone most adjacent to the pubic symphysis. Intra-observer repeatability was determined and analysis of variance was performed to assess inter-observer measurements. The bias between any two sonographers’ measurements was assessed by calculating the 95% confidence interval for the mean difference between sonographers paired measurements. Results: Intra-observer reproducibility was 0.71 cm. Analysis of variance indicated that there was no significant difference between sonographers’ measurements (p = 0.46). The bias between two sonographers’ measurements ranged from 0.05 to 0.32 cm. Conclusion: It is technically feasible to measure the pelvic inlet diameter using ultrasound (USG) at the first trimester. High inter-observer reproducibility can be achieved. Further studies are required to establish the potential role of this technique and the measurement of the pelvic inlet diameter in prediction of labor outcome. Objectives: To determine intra- and inter-observer reproducibility of the ultrasound measurement of pelvic inlet in the first trimester of pregnancy. Methods: Transabdominal pelvic ultrasound was performed to measure the pelvic inlet anteroposterior diameter using a 2D probe in twelve Chinese women having a singleton pregnancy. Scans were performed in the first trimester by three sonographers. The pelvic inlet anteroposterior diameter was defined as the distance between the anterior surfaces of the sacral promontory and the superior medial border of the pubic bone most adjacent to the pubic symphysis. Intra-observer repeatability was determined and analysis of variance was performed to assess inter-observer measurements. The bias between any two sonographers’ measurements was assessed by calculating the 95% confidence interval for the mean difference between sonographers paired measurements. Results: Intra-observer reproducibility was 0.71 cm. Analysis of variance indicated that there was no significant difference between sonographers’ measurements (p = 0.46). The bias between two sonographers’ measurements ranged from 0.05 to 0.32 cm. Conclusion: It is technically feasible to measure the pelvic inlet diameter using ultrasound (USG) at the first trimester. High inter-observer reproducibility can be achieved. Further studies are required to establish the potential role of this technique and the measurement of the pelvic inlet diameter in prediction of labor outcome.
出处 《Open Journal of Obstetrics and Gynecology》 2014年第11期653-658,共6页 妇产科期刊(英文)
关键词 PELVIMETRY PELVIC INLET DIAMETER OBSTETRIC Conjugate Pelvimetry Pelvic Inlet Diameter Obstetric Conjugate
  • 相关文献

同被引文献3

引证文献1

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部