期刊文献+

Sonopelvimetry: An Innovative Method for Early Prediction of Obstructed Labour 被引量:1

Sonopelvimetry: An Innovative Method for Early Prediction of Obstructed Labour
下载PDF
导出
摘要 Aim: To evaluate an innovative sonopelvimetry method for early prediction of obstructed labour. Methods: A prospective study was conducted in two centers.GPS-based sonopelvimetry, laborProTM?(Trig Medical Inc., Yoqneam Ilit, Israel) devise, was used prior to labour in nulliparous women at 39 - 42 weeks gestation remote from labor. Maternal pelvic parameters, including inter-iliac transverse diameter, obstetric conjugate and interspinous diameter were evaluated. Fetal parameters included head station, biparietal diameter and occipitofrontal diameter. Data on delivery and outcome were collected from the electronic files. Results: The innovative use of sonopelvimetry was applied to 154 consecutive women, none of the participants complained of discomfort or complications observed. The mean time of examination was 15 + 2 minutes. Mean time of examination to delivery interval was 4.8 days (range 0 - 16 days). Small interspinous diameter and high head station were the best predictors for obstructed labour. Analysis indicated 87% sensitivity and 61% specificity for birth weight fetal head station and ISD combined in predicting obstructed labour with an area under the curve of 0.77. Conclusions: Our results indicate that GPS-based?sonopelvimetry combined with fetal estimated weight is a valuable tool in the risk assessment of obstructed labour. Parameters obtained by sonopelvimetry combined with birth weight may be useful. Aim: To evaluate an innovative sonopelvimetry method for early prediction of obstructed labour. Methods: A prospective study was conducted in two centers.GPS-based sonopelvimetry, laborProTM?(Trig Medical Inc., Yoqneam Ilit, Israel) devise, was used prior to labour in nulliparous women at 39 - 42 weeks gestation remote from labor. Maternal pelvic parameters, including inter-iliac transverse diameter, obstetric conjugate and interspinous diameter were evaluated. Fetal parameters included head station, biparietal diameter and occipitofrontal diameter. Data on delivery and outcome were collected from the electronic files. Results: The innovative use of sonopelvimetry was applied to 154 consecutive women, none of the participants complained of discomfort or complications observed. The mean time of examination was 15 + 2 minutes. Mean time of examination to delivery interval was 4.8 days (range 0 - 16 days). Small interspinous diameter and high head station were the best predictors for obstructed labour. Analysis indicated 87% sensitivity and 61% specificity for birth weight fetal head station and ISD combined in predicting obstructed labour with an area under the curve of 0.77. Conclusions: Our results indicate that GPS-based?sonopelvimetry combined with fetal estimated weight is a valuable tool in the risk assessment of obstructed labour. Parameters obtained by sonopelvimetry combined with birth weight may be useful.
出处 《Open Journal of Obstetrics and Gynecology》 2014年第13期757-765,共9页 妇产科期刊(英文)
关键词 FOETAL HEAD STATION Interspinous DIAMETER OBSTRUCTED Labour Sonopelvimetry Foetal Head Station Interspinous Diameter Obstructed Labour Sonopelvimetry
  • 相关文献

同被引文献7

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部