Effect of Fetal Movements and Fetal Breathing on Fetal Middle Cerebral Artery Pulsatility Index Measurement

Effect of Fetal Movements and Fetal Breathing on Fetal Middle Cerebral Artery Pulsatility Index Measurement
下载PDF
导出
摘要 Objective: This study aimed to determine the effect of fetal movements on the MCA pulsatility index (PI) and quantify the fall of MCA PI after initiation of fetal movements and/or breathing, and the time taken to recover from a fall below the 5th percentile. Methods: 16 women with appropriate for gestational age (AGA) fetuses and 16 women with small for gestational age (SGA) fetuses were recruited. MCA PI during “no movement” state was compared with MCA PI values during fetal body movements and breathing movements. Results: MCA PI measurements with body or breathing movements were significantly (p 0.005) lower as compared to that observed without movements. MCA PI started rising immediately after cessation of body movements and/or breathing movements. Conclusions: MCA PI with fetal body or breathing movements is significantly lower as compared to that observed in the quiet state. If MCA PI measurement is below 5th centile, it should be measured again up to 90 seconds after cessation of fetal body and/or breathing movements in order to minimize false positive diagnosis of cerebral sparing effect in SGA as well as AGA fetuses. Objective: This study aimed to determine the effect of fetal movements on the MCA pulsatility index (PI) and quantify the fall of MCA PI after initiation of fetal movements and/or breathing, and the time taken to recover from a fall below the 5th percentile. Methods: 16 women with appropriate for gestational age (AGA) fetuses and 16 women with small for gestational age (SGA) fetuses were recruited. MCA PI during “no movement” state was compared with MCA PI values during fetal body movements and breathing movements. Results: MCA PI measurements with body or breathing movements were significantly (p 0.005) lower as compared to that observed without movements. MCA PI started rising immediately after cessation of body movements and/or breathing movements. Conclusions: MCA PI with fetal body or breathing movements is significantly lower as compared to that observed in the quiet state. If MCA PI measurement is below 5th centile, it should be measured again up to 90 seconds after cessation of fetal body and/or breathing movements in order to minimize false positive diagnosis of cerebral sparing effect in SGA as well as AGA fetuses.
出处 《Open Journal of Obstetrics and Gynecology》 2018年第4期354-361,共8页 妇产科期刊(英文)
关键词 Variation of FETAL MCA PI FETAL MCA DOPPLER FETAL Movements FETAL BREATHING ANTENATAL DOPPLER Cerebral Sparing EFFECT Variation of Fetal MCA PI Fetal MCA Doppler Fetal Movements Fetal Breathing Antenatal Doppler Cerebral Sparing Effect
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部