期刊文献+

Comparison between the PlusoptiX and IScreen Photoscreeners in Detecting Amblyopic Risk Factors in Children

Comparison between the PlusoptiX and IScreen Photoscreeners in Detecting Amblyopic Risk Factors in Children
下载PDF
导出
摘要 Purpose: To compare the accuracy of plusoptiX A08 photoscreener (PPS) and iScreen 3000 photoscreener (IPS) in objectively screening for amblyopic risk factors in children age 5 months to 13 years old. Methods: Cross-sectional study of 148 children who received photoscreenings via PPS and IPS and a comprehensive pediatric ophthalmic examination in our office. Patients were considered to have amblyogenic risk factors based on the AAPOS referral criteria guidelines. Results: 45 percent of patients undergoing a pediatric ophthalmology examination were found to have amblyopia or amblyogenic risk factors. In this study, PPS demonstrated an overall sensitivity of 75.4%, specificity of 68.0%, positive predictive value (PPV) of 67.1%, and negative predictive value (NPV) of 76.1%. However, IPS photoscreener had an overall sensitivity of 66.2%, specificity of 87.6%, PPV of 81.8%, and NPV of 75.5%. Discussion: The accuracy of PPS and IPS was compared in different age groups. The sensitivity and specificity were analyzed according to varied amblyogenic risk factors. The statistic results of this study were compared to those of previous studies, including Vision in Preschoolers (VIP) Study and the Iowa PhotoScreening Program. Conclusion: PPS and IPS proved to be useful tools in the objective vision screening in children. PPS was found to have a higher sensitivity, and IPS showed a higher specificity and PPV in detecting amblyopic risk factors. In conclusion, one device may be more beneficial over the other, depending on the patient population and office settings. Purpose: To compare the accuracy of plusoptiX A08 photoscreener (PPS) and iScreen 3000 photoscreener (IPS) in objectively screening for amblyopic risk factors in children age 5 months to 13 years old. Methods: Cross-sectional study of 148 children who received photoscreenings via PPS and IPS and a comprehensive pediatric ophthalmic examination in our office. Patients were considered to have amblyogenic risk factors based on the AAPOS referral criteria guidelines. Results: 45 percent of patients undergoing a pediatric ophthalmology examination were found to have amblyopia or amblyogenic risk factors. In this study, PPS demonstrated an overall sensitivity of 75.4%, specificity of 68.0%, positive predictive value (PPV) of 67.1%, and negative predictive value (NPV) of 76.1%. However, IPS photoscreener had an overall sensitivity of 66.2%, specificity of 87.6%, PPV of 81.8%, and NPV of 75.5%. Discussion: The accuracy of PPS and IPS was compared in different age groups. The sensitivity and specificity were analyzed according to varied amblyogenic risk factors. The statistic results of this study were compared to those of previous studies, including Vision in Preschoolers (VIP) Study and the Iowa PhotoScreening Program. Conclusion: PPS and IPS proved to be useful tools in the objective vision screening in children. PPS was found to have a higher sensitivity, and IPS showed a higher specificity and PPV in detecting amblyopic risk factors. In conclusion, one device may be more beneficial over the other, depending on the patient population and office settings.
出处 《Open Journal of Ophthalmology》 2013年第1期7-12,共6页 眼科学期刊(英文)
关键词 Amblyogenic RISK FACTORS Photoscreeners Amblyogenic Risk Factors Photoscreeners
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部