期刊文献+

Refractive Outcomes Using the Lenstar Optical Low Coherence Reflectometry Biometer in Phacovitrectomy for Epiretrinal Membranes and Macular Holes 被引量:2

Refractive Outcomes Using the Lenstar Optical Low Coherence Reflectometry Biometer in Phacovitrectomy for Epiretrinal Membranes and Macular Holes
下载PDF
导出
摘要 Objective: To compare refractive outcomes using the Lenstar optical low-coherence reflectometry (OLCR) biometer in the following cases: phacovitrectomy for epiretinal membranes and macular holes (phacovitrectomy group);sequential cataract surgery after prior vitrectomy (sequential-phaco group);routine cataract surgery (phaco-only group). Methods: This study was a retrospective, consecutive comparative series. Main outcomes were mean prediction error (ME) and mean absolute prediction error (MAE). Secondary out-come was the variance in prediction error. Results: ME was significantly more myopic in the phacovitrectomy group (-0.08 ± 0.77D, mean ± SD, p = 0.04) and the sequentialphaco group (-0.09 ± 0.51D, p = 0.01) compared to the phaco-only group (+0.24 ± 0.53D). MAEs were not statistically different across the 3 groups. The phacovitrectomy group had a wider variance in prediction errors compared to the phaco-only group (p = 0.03). Conclusions: There is a myopic shift of approximately -0.3D in both phacovitrectomy and sequential-phaco cases compared to phaco-only cases when using OLCR-based optical biometry. Phacovitrectomy outcomes are more variable compared to phaco-only eyes. Objective: To compare refractive outcomes using the Lenstar optical low-coherence reflectometry (OLCR) biometer in the following cases: phacovitrectomy for epiretinal membranes and macular holes (phacovitrectomy group);sequential cataract surgery after prior vitrectomy (sequential-phaco group);routine cataract surgery (phaco-only group). Methods: This study was a retrospective, consecutive comparative series. Main outcomes were mean prediction error (ME) and mean absolute prediction error (MAE). Secondary out-come was the variance in prediction error. Results: ME was significantly more myopic in the phacovitrectomy group (-0.08 ± 0.77D, mean ± SD, p = 0.04) and the sequentialphaco group (-0.09 ± 0.51D, p = 0.01) compared to the phaco-only group (+0.24 ± 0.53D). MAEs were not statistically different across the 3 groups. The phacovitrectomy group had a wider variance in prediction errors compared to the phaco-only group (p = 0.03). Conclusions: There is a myopic shift of approximately -0.3D in both phacovitrectomy and sequential-phaco cases compared to phaco-only cases when using OLCR-based optical biometry. Phacovitrectomy outcomes are more variable compared to phaco-only eyes.
出处 《Open Journal of Ophthalmology》 2017年第3期216-224,共9页 眼科学期刊(英文)
关键词 Refractive OUTCOMES Phacovitrectomy OPTICAL BIOMETRY LENSTAR OLCR Refractive Outcomes Phacovitrectomy Optical Biometry Lenstar OLCR
  • 相关文献

同被引文献6

引证文献2

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部