期刊文献+

Development of a Retractor Holding Device to Reduce the Manpower in Total Hip Arthroplasty through Direct Anterior Approach

Development of a Retractor Holding Device to Reduce the Manpower in Total Hip Arthroplasty through Direct Anterior Approach
下载PDF
导出
摘要 Direct anterior approach (DAA) for total hip arthroplasty (THA) is a minimally invasive technique. In this approach, two assistants are necessary. We developed a retractor holding device called “Spider arm” to replace an assistant in the contra-lateral side. In this study, we investigated the usefulness of Spider arm in THA through direct anterior approach. 20 hips were operated without Spider arm and 21 hips were operated with Spider arm. The surgery time and the blood loss were compared. The cup position and leg length discrepancy were measured on radiography. There was no statistical significance between two groups in all parameters. No clinical complications were reported. With Spider arm, DAA-THA could be performed by two surgeons without deterioration of the surgery time and blood loss. The accuracy of cup position and leg length discrepancy was not affected. Spider arm can contribute to reducing the manpower in DAA-THA. Direct anterior approach (DAA) for total hip arthroplasty (THA) is a minimally invasive technique. In this approach, two assistants are necessary. We developed a retractor holding device called “Spider arm” to replace an assistant in the contra-lateral side. In this study, we investigated the usefulness of Spider arm in THA through direct anterior approach. 20 hips were operated without Spider arm and 21 hips were operated with Spider arm. The surgery time and the blood loss were compared. The cup position and leg length discrepancy were measured on radiography. There was no statistical significance between two groups in all parameters. No clinical complications were reported. With Spider arm, DAA-THA could be performed by two surgeons without deterioration of the surgery time and blood loss. The accuracy of cup position and leg length discrepancy was not affected. Spider arm can contribute to reducing the manpower in DAA-THA.
作者 Hirotake Yo Hirotsugu Ohashi Ryo Sugama Tessyu Ikawa Hirotake Yo;Hirotsugu Ohashi;Ryo Sugama;Tessyu Ikawa(Department of Orthopaedic Surgery, Osaka Saiseikai Nakatsu Hospital, Osaka, Japan)
出处 《Open Journal of Orthopedics》 2016年第2期23-28,共6页 矫形学期刊(英文)
关键词 Retractor Holding Device Spider Arm Direct Anterior Approach Hip Arthroplasty Retractor Holding Device Spider Arm Direct Anterior Approach Hip Arthroplasty
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部