期刊文献+

Counting Steps in Research: A Comparison of Accelerometry and Pedometry

Counting Steps in Research: A Comparison of Accelerometry and Pedometry
下载PDF
导出
摘要 The objective of this study was to assess the validity of the step count functions in Actical accelerometers and activPAL inclinometers, compared with pedome-ter-derived step count data. Firstly, directly observed step counts over 3 treadmill speeds were compared with steps collected from 3 pedometers, accelerometers, and inclinometers in 10 adults. Secondly, step count data were derived from 22 participants who wore a pedome-ter, accelerometer, and inclinometer over 48 hours. Agreement between measurement tools was determined. All monitors appropriately measured steps in the labo-ratory conditions. In free living conditions, the mean percentage differences with pedometer-determined step counts were -7.3% and 7.0% for the Actical and ac-tivPAL monitors, respectively. With the exception of slow walking for the Actical units (ICC < 0.001), acceptable reliability was found within units for all treadmill speeds, and across units during the free living condition. The 95% prediction interval ranges were wide, ranging from -68.8% to 54.2% for the Acticals, and from -39.1% to 53.2% for the activPALs. Step counts gathered from Actical and activPAL units should not be used interchangeably with pedometer-derived step count data. The objective of this study was to assess the validity of the step count functions in Actical accelerometers and activPAL inclinometers, compared with pedome-ter-derived step count data. Firstly, directly observed step counts over 3 treadmill speeds were compared with steps collected from 3 pedometers, accelerometers, and inclinometers in 10 adults. Secondly, step count data were derived from 22 participants who wore a pedome-ter, accelerometer, and inclinometer over 48 hours. Agreement between measurement tools was determined. All monitors appropriately measured steps in the labo-ratory conditions. In free living conditions, the mean percentage differences with pedometer-determined step counts were -7.3% and 7.0% for the Actical and ac-tivPAL monitors, respectively. With the exception of slow walking for the Actical units (ICC < 0.001), acceptable reliability was found within units for all treadmill speeds, and across units during the free living condition. The 95% prediction interval ranges were wide, ranging from -68.8% to 54.2% for the Acticals, and from -39.1% to 53.2% for the activPALs. Step counts gathered from Actical and activPAL units should not be used interchangeably with pedometer-derived step count data.
机构地区 不详
出处 《Open Journal of Preventive Medicine》 2011年第1期1-7,共7页 预防医学期刊(英文)
关键词 Physical activity Measurement PEDOMETER INCLINOMETER ACCELEROMETER Validation Reliability Physical activity Measurement Pedometer Inclinometer Accelerometer Validation Reliability
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部