期刊文献+

Evaluation of Teeth Discoloration Induced by Endomethasone, AH+, Canason and Apexit Paste 被引量:1

Evaluation of Teeth Discoloration Induced by Endomethasone, AH+, Canason and Apexit Paste
下载PDF
导出
摘要 Objective: The aim of this study was to investigate, in vitro, the color changes of the teeth, induced by endodontic sealers. Materials and Methods: Forty-five mature maxillary and mandibular anterior teeth, extracted for periodontal reasons, were collected. After the chemo-mechanical instrumentation of the root canal, teeth were filled with four endodontic sealers (Endomethason, AH+, Canason and Apexit). Depending on canal sealers and the CEJ (Cement Enamel Junction), teeth were divided into 8 experimental groups (n = 5) and one control group/CG (n = 5). Teeth color changes (L*a*b*/CIE Commission Internationaled’ Eclaraige) were determinated by a spectrophotometer Vita Easyshade in 4 stages (Baseline, Week 0, 4 and 12). Results: Between the EOCEJ and CG for the parameter L*, there was a statistical significance (p 0.05). The L*a*b* results were: L* (83.6 ± 4.8 → 83.6 ± 4.9);a* (﹣2.68 ± 1.02 → ﹣1.12 ± 0.72) and b* (20.2 ± 4.5 → 24.4 ± 4.2). Conclusions: All endodontic sealers may cause teeth discoloration. Objective: The aim of this study was to investigate, in vitro, the color changes of the teeth, induced by endodontic sealers. Materials and Methods: Forty-five mature maxillary and mandibular anterior teeth, extracted for periodontal reasons, were collected. After the chemo-mechanical instrumentation of the root canal, teeth were filled with four endodontic sealers (Endomethason, AH+, Canason and Apexit). Depending on canal sealers and the CEJ (Cement Enamel Junction), teeth were divided into 8 experimental groups (n = 5) and one control group/CG (n = 5). Teeth color changes (L*a*b*/CIE Commission Internationaled’ Eclaraige) were determinated by a spectrophotometer Vita Easyshade in 4 stages (Baseline, Week 0, 4 and 12). Results: Between the EOCEJ and CG for the parameter L*, there was a statistical significance (p 0.05). The L*a*b* results were: L* (83.6 ± 4.8 → 83.6 ± 4.9);a* (﹣2.68 ± 1.02 → ﹣1.12 ± 0.72) and b* (20.2 ± 4.5 → 24.4 ± 4.2). Conclusions: All endodontic sealers may cause teeth discoloration.
出处 《Open Journal of Stomatology》 2014年第12期507-517,共11页 口腔学期刊(英文)
关键词 DISCOLORATION ENDODONTIC Sealers SPECTROPHOTOMETER Discoloration Endodontic Sealers Spectrophotometer
  • 相关文献

同被引文献11

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部