期刊文献+

I Do Biotech Dental Implants: Prospective Multicentric Study after 5 Years of Functional Loading

I Do Biotech Dental Implants: Prospective Multicentric Study after 5 Years of Functional Loading
下载PDF
导出
摘要 <b><span style="font-family:Verdana;">Introduction:</span></b><span style="font-family:Verdana;"> I Do Biotech’s implants were developed starting in 2014. Since then, they obtained GMP and KFDA licenses for distribution in 2015. The main objective of this paper is to determine the survival rate of I Do Biotech implants five years after the first surgery.</span><span style="font-family:Verdana;"> </span><b><span style="font-family:Verdana;">Material and Methods:</span></b><span style="font-family:Verdana;"> 1000 implants were used on 480 prosthes</span><span style="font-family:Verdana;">e</span><span style="font-family:Verdana;">s across 10 clinics on 320 healthy, non-smoker and non-diabetic patients, chosen at random, of which 160 are male and 160 female, all in the age range of 30 to 50 years old. The failure rate was studied related to the patient’s gender, the length and diameter of the implant, anatomical location, the percentage of peri-implantitis, prosthodontic failures and the patient’s quality of life.</span><span style="font-family:Verdana;"> </span><b><span style="font-family:Verdana;">Discussion:</span></b><span style="font-family:Verdana;"> The results obtained are similar to those of Van Steenberghe D. Dieter-Busenlechner, E. Serrano Catauria and far superior to those of Sáenz Guzmán. Failure rates vary greatly from study to study due to the heterogeneity of the samples in the other research papers. </span><b><span style="font-family:Verdana;">Conclusion:</span></b><span style="font-family:Verdana;"> The overall implant failure rate at 5 years is 1.7%. The factors affecting significantly the survival rate are: the implant diameter, its length and the anatomic area. Failure ratios increase significantly when the diameter or the length of the implant decrease</span><span style="font-family:Verdana;">s</span><span style="font-family:Verdana;">, and when they are placed in the posterior maxilla (up to 4.3%).</span><span style="font-family:Verdana;"> </span><span style="font-family:Verdana;">The rate of peri-implantitis is 5.1%. The prosthodontic failure rate is 2.91%. The improvement in quality of life and satisfaction increases with the years.</span> <b><span style="font-family:Verdana;">Introduction:</span></b><span style="font-family:Verdana;"> I Do Biotech’s implants were developed starting in 2014. Since then, they obtained GMP and KFDA licenses for distribution in 2015. The main objective of this paper is to determine the survival rate of I Do Biotech implants five years after the first surgery.</span><span style="font-family:Verdana;"> </span><b><span style="font-family:Verdana;">Material and Methods:</span></b><span style="font-family:Verdana;"> 1000 implants were used on 480 prosthes</span><span style="font-family:Verdana;">e</span><span style="font-family:Verdana;">s across 10 clinics on 320 healthy, non-smoker and non-diabetic patients, chosen at random, of which 160 are male and 160 female, all in the age range of 30 to 50 years old. The failure rate was studied related to the patient’s gender, the length and diameter of the implant, anatomical location, the percentage of peri-implantitis, prosthodontic failures and the patient’s quality of life.</span><span style="font-family:Verdana;"> </span><b><span style="font-family:Verdana;">Discussion:</span></b><span style="font-family:Verdana;"> The results obtained are similar to those of Van Steenberghe D. Dieter-Busenlechner, E. Serrano Catauria and far superior to those of Sáenz Guzmán. Failure rates vary greatly from study to study due to the heterogeneity of the samples in the other research papers. </span><b><span style="font-family:Verdana;">Conclusion:</span></b><span style="font-family:Verdana;"> The overall implant failure rate at 5 years is 1.7%. The factors affecting significantly the survival rate are: the implant diameter, its length and the anatomic area. Failure ratios increase significantly when the diameter or the length of the implant decrease</span><span style="font-family:Verdana;">s</span><span style="font-family:Verdana;">, and when they are placed in the posterior maxilla (up to 4.3%).</span><span style="font-family:Verdana;"> </span><span style="font-family:Verdana;">The rate of peri-implantitis is 5.1%. The prosthodontic failure rate is 2.91%. The improvement in quality of life and satisfaction increases with the years.</span>
作者 J. F. Ballester Ferrandis Song Jae Hyun Kim Jong Yeon Anaraki Mohaammad Varun Goel Shaker Tarawneh Ming Yang De Darabi Mohammadreza Ysang Century Tian Han Qing S. J. Ballester Bon J. F. Ballester Ferrandis;Song Jae Hyun;Kim Jong Yeon;Anaraki Mohaammad;Varun Goel;Shaker Tarawneh;Ming Yang;De Darabi Mohammadreza;Ysang Century;Tian Han Qing;S. J. Ballester Bon(Postgraduate Implantology Program at UFP-ESORIB, Madrid, Spain)
出处 《Open Journal of Stomatology》 2020年第6期121-139,共19页 口腔学期刊(英文)
关键词 Dental Implants Titanium Morse Taper SLA Surface Multicentric Study PERI-IMPLANTITIS Prosthodontic Failures Study after 5 Years of Loading Quality of Life Dental Implants Titanium Morse Taper SLA Surface Multicentric Study Peri-Implantitis Prosthodontic Failures Study after 5 Years of Loading Quality of Life
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部