期刊文献+

Compliant to Warfarin Therapy after Mechanical Heart Valve Replacement

Compliant to Warfarin Therapy after Mechanical Heart Valve Replacement
下载PDF
导出
摘要 Introduction: Effective anticoagulation depends on demographic factors, patient education, drug knowledge and compliance. The aim of our study is to determine the factors that influence compliance to warfarin in the mechanical valve patient population and its relationship with thrombo-embolic and bleeding events. Patients and Methods: 113 patients underwent mechanical valve replacement (Aortic, mitral or both) at King Abdul-Aziz University Hospital, from 2006 to 2012, patients divided into two groups according to warfarin compliant. Results: 113 patients reviewed in our study, 69 (61.1%) patients found compliant, 36 (31.9%) patients found non compliant, and 8 (7.1%) patients missed. The mean age for all patients was 39.25 y: 76 (67.3%) ware male, 37 (32.7%) were female. Mean age for compliant patients was 40.19 y versus 33.3 y for noncompliant patients with p value 0.017. Male patient less complaint than female with significant 0.01, the mean frequency of follow up was less (32.32 days) in compliant vs. (67.73 days) in non complaint patient. Conclusion: younger age, female gender, Arabic race, assistance at home, education, and single drug use are factors associated with patient compliant, non compliance are associated with higher mortality and valve related complication. Introduction: Effective anticoagulation depends on demographic factors, patient education, drug knowledge and compliance. The aim of our study is to determine the factors that influence compliance to warfarin in the mechanical valve patient population and its relationship with thrombo-embolic and bleeding events. Patients and Methods: 113 patients underwent mechanical valve replacement (Aortic, mitral or both) at King Abdul-Aziz University Hospital, from 2006 to 2012, patients divided into two groups according to warfarin compliant. Results: 113 patients reviewed in our study, 69 (61.1%) patients found compliant, 36 (31.9%) patients found non compliant, and 8 (7.1%) patients missed. The mean age for all patients was 39.25 y: 76 (67.3%) ware male, 37 (32.7%) were female. Mean age for compliant patients was 40.19 y versus 33.3 y for noncompliant patients with p value 0.017. Male patient less complaint than female with significant 0.01, the mean frequency of follow up was less (32.32 days) in compliant vs. (67.73 days) in non complaint patient. Conclusion: younger age, female gender, Arabic race, assistance at home, education, and single drug use are factors associated with patient compliant, non compliance are associated with higher mortality and valve related complication.
出处 《Open Journal of Thoracic Surgery》 2014年第2期39-43,共5页 胸外科期刊(英文)
关键词 WARFARIN Compliant MECHANICAL VALVE REPLACEMENT Warfarin Compliant Mechanical Valve Replacement
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部