期刊文献+

Factors Associated with Sample Rejection for CD4+/CD8+ T Cell Count Analyses at the Kenyatta National Hospital Comprehensive Care Center Laboratory, Kenya

Factors Associated with Sample Rejection for CD4+/CD8+ T Cell Count Analyses at the Kenyatta National Hospital Comprehensive Care Center Laboratory, Kenya
下载PDF
导出
摘要 <strong><em>Background: </em></strong>The appropriate time to initiate antiretroviral therapy (ART) in HIV/AIDS patients is determined by measurement of CD4+/CD8+ T cell count. The CD4/CD8+ T cell count is also useful, together with viral load, in monitoring disease progression and effectiveness treatment regimens. Several factors may contribute to sample rejection during the CD4+/CD8+ T cells count, resulting in negative effects on patient management. <strong> <em>Objective: </em></strong>Evaluate the causes for CD4+CD8+ T cell count sample rejection at the Kenyatta National Hospital Comprehensive Care Center Laboratory. <strong><em>Method:</em></strong> A retrospective cross-sectional study was conducted between 2018 and 2020. Data was obtained from the “rejected samples” for Partec<sup>R</sup> FlowCyp flow cytometry file. Designed data collection sheet was used for data capture. A total of 3972 samples were submitted for CD4+/CD8+ T cell count during the study period. Causes for sample rejection were numbered 1 to 12, each representing a reason for sample rejection. Number 1 was sub-categorized into clotted, hemolyzed, short-draw and lipemic. Data was analyzed using excel, and presented using tables, graphs and pie charts. Approval to conduct the study was obtained from KNH/UoN ERC. <strong> <em>Results:  </em></strong>In the study period, 81/3972 (2.0%) samples were rejected. Samples submitted more than 48 hours after collection were mostly rejected. Other factors included improper collection technique, delayed testing, patient identification error and incorrect use of vacutainer. A combination of clotted samples, specimen submission more than 48 hours caused the most frequent sample rejection, followed with combination of specimen submission more than 48 hours, delayed testing and delayed specimen processing. Together, clotted samples, incorrect vacutainer and poor specimen label caused the least sample rejection. <strong><em>Conclusion:</em></strong> Sample rejection rate for CD4/CD8+ T cell count was relatively low, and multiple factors contributed to rejection. However, improved quality assurance will enable more benefit to patients who seek this test in the laboratory. <strong><em>Background: </em></strong>The appropriate time to initiate antiretroviral therapy (ART) in HIV/AIDS patients is determined by measurement of CD4+/CD8+ T cell count. The CD4/CD8+ T cell count is also useful, together with viral load, in monitoring disease progression and effectiveness treatment regimens. Several factors may contribute to sample rejection during the CD4+/CD8+ T cells count, resulting in negative effects on patient management. <strong> <em>Objective: </em></strong>Evaluate the causes for CD4+CD8+ T cell count sample rejection at the Kenyatta National Hospital Comprehensive Care Center Laboratory. <strong><em>Method:</em></strong> A retrospective cross-sectional study was conducted between 2018 and 2020. Data was obtained from the “rejected samples” for Partec<sup>R</sup> FlowCyp flow cytometry file. Designed data collection sheet was used for data capture. A total of 3972 samples were submitted for CD4+/CD8+ T cell count during the study period. Causes for sample rejection were numbered 1 to 12, each representing a reason for sample rejection. Number 1 was sub-categorized into clotted, hemolyzed, short-draw and lipemic. Data was analyzed using excel, and presented using tables, graphs and pie charts. Approval to conduct the study was obtained from KNH/UoN ERC. <strong> <em>Results:  </em></strong>In the study period, 81/3972 (2.0%) samples were rejected. Samples submitted more than 48 hours after collection were mostly rejected. Other factors included improper collection technique, delayed testing, patient identification error and incorrect use of vacutainer. A combination of clotted samples, specimen submission more than 48 hours caused the most frequent sample rejection, followed with combination of specimen submission more than 48 hours, delayed testing and delayed specimen processing. Together, clotted samples, incorrect vacutainer and poor specimen label caused the least sample rejection. <strong><em>Conclusion:</em></strong> Sample rejection rate for CD4/CD8+ T cell count was relatively low, and multiple factors contributed to rejection. However, improved quality assurance will enable more benefit to patients who seek this test in the laboratory.
作者 Moherai Wilfred Felix Joshua Nyagol Walter Mwanda Moherai Wilfred Felix;Joshua Nyagol;Walter Mwanda(Department of Human Pathology, Thematic Unit of Immunology, University of Nairobi, Nairobi, Kenya;Department of Human Pathology, Thematic Unit of Hematology and Blood Transfusion Unit, University of Nairobi, Nairobi, Kenya)
出处 《World Journal of AIDS》 2021年第4期181-188,共8页 艾滋病(英文)
关键词 SAMPLE REJECTION Causes CD4/CD8+ T Cell Count Flow Cytometry Sample Rejection Causes CD4/CD8+ T Cell Count Flow Cytometry
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部