摘要 Background and Aim: Newer generation coronary stent systems with low profile metallic frame, biodegradable polymer coating and potent but safe anti-restenosis drug from “limus family” are emerging as safe and effective stents. To evaluate the safety and performance of Metafor SES (Meril life Sciences Pvt. Ltd., Vapi, India) in consecutive patients in a real-world population. Methods: The study was a retrospective, non-randomized, single-center study which evaluated the data of 127 patients who underwent percutaneous coronary intervention (PCI) treated with Metafor SES from February 2012 to February 2015 and mean follow-up period of those patients was 3.6 ± 0.6 years. The primary endpoint was a major adverse cardiac event (MACE) including cardiac death, myocardial infarction (MI), and target lesion revascularization (TLR). In addition, Stent thrombosis (ST) was analyzed at respective follow-up period. Results: A total of 127 patients (mean age: 53.70 ± 8.41 years and 99 males) were included. Among those 80 (63%) patients had hypertension and 58 (45.7%) patients with diabetes mellitus.At follow-up, MACE in form of TLR was observed in 2 (1.6%) patients only. No cardiac death or stent thrombosis was reported in any patient. A total of 169 lesions were treated with the Metafor SES (1.3 stents per lesion). The 38.4% of patients treated with the Metafor SES with lesion length ≥24 mm, and the procedural success was 100%. Conclusions: The lower incidence of MACE in uncontrolled and real world population at long term follow-up clearly depicts the prolonged safety and performance of the Metafor SES. Background and Aim: Newer generation coronary stent systems with low profile metallic frame, biodegradable polymer coating and potent but safe anti-restenosis drug from “limus family” are emerging as safe and effective stents. To evaluate the safety and performance of Metafor SES (Meril life Sciences Pvt. Ltd., Vapi, India) in consecutive patients in a real-world population. Methods: The study was a retrospective, non-randomized, single-center study which evaluated the data of 127 patients who underwent percutaneous coronary intervention (PCI) treated with Metafor SES from February 2012 to February 2015 and mean follow-up period of those patients was 3.6 ± 0.6 years. The primary endpoint was a major adverse cardiac event (MACE) including cardiac death, myocardial infarction (MI), and target lesion revascularization (TLR). In addition, Stent thrombosis (ST) was analyzed at respective follow-up period. Results: A total of 127 patients (mean age: 53.70 ± 8.41 years and 99 males) were included. Among those 80 (63%) patients had hypertension and 58 (45.7%) patients with diabetes mellitus.At follow-up, MACE in form of TLR was observed in 2 (1.6%) patients only. No cardiac death or stent thrombosis was reported in any patient. A total of 169 lesions were treated with the Metafor SES (1.3 stents per lesion). The 38.4% of patients treated with the Metafor SES with lesion length ≥24 mm, and the procedural success was 100%. Conclusions: The lower incidence of MACE in uncontrolled and real world population at long term follow-up clearly depicts the prolonged safety and performance of the Metafor SES.
出处 《World Journal of Cardiovascular Diseases》 2017年第5期163-173,共11页 心血管病(英文)
关键词 BIODEGRADABLE Polymer Cobalt-Chromium Metafor SES Sirolimus-Eluting STENT STENT THROMBOSIS Biodegradable Polymer Cobalt-Chromium Metafor SES Sirolimus-Eluting Stent Stent Thrombosis
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部