期刊文献+

Fault Location Method for STATCOM Connected Transmission Lines Using CCM 被引量:1

Fault Location Method for STATCOM Connected Transmission Lines Using CCM
下载PDF
导出
摘要 Determining the fault location using conventional impedance based distance relay in the presence of FACTS controllers is a challenging task in a transmission line. A new distance protection method is developed to locate the fault in a transmission line compensated with STATCOM with simple calculations. The proposed protection method considers the STATCOM injected/absorbed current to correct the fault loop apparent impedance and accordingly calculates the actual distance to the fault location. The comprehensive equations needed for apparent impedance calculation are also outlined and the performance is evaluated and tested with a typical 400 KV transmission system for different fault types and locations using MATLAB/SIMULINK software. The evaluation results indicate that the new protection method effectively estimates the exact fault location by mitigating the impact of STATCOM on distance relay performance with error less than 0.3%. Determining the fault location using conventional impedance based distance relay in the presence of FACTS controllers is a challenging task in a transmission line. A new distance protection method is developed to locate the fault in a transmission line compensated with STATCOM with simple calculations. The proposed protection method considers the STATCOM injected/absorbed current to correct the fault loop apparent impedance and accordingly calculates the actual distance to the fault location. The comprehensive equations needed for apparent impedance calculation are also outlined and the performance is evaluated and tested with a typical 400 KV transmission system for different fault types and locations using MATLAB/SIMULINK software. The evaluation results indicate that the new protection method effectively estimates the exact fault location by mitigating the impact of STATCOM on distance relay performance with error less than 0.3%.
作者 R. Ilango T. Sree Renga Raja R. Ilango;T. Sree Renga Raja(Department of Electrical and Electronics Engineering, M.A.M. School of Engineering, Tiruchirappalli, India;Department of Electrical and Electronics Engineering, Anna University, BIT Campus, Tiruchirappalli, India)
出处 《Circuits and Systems》 2016年第10期3131-3141,共12页 电路与系统(英文)
关键词 Distance Relay Fault Location Flexible AC Transmission Systems (FACTS) Power System Protection Static Synchronous Compensator (STATCOM) Distance Relay Fault Location Flexible AC Transmission Systems (FACTS) Power System Protection Static Synchronous Compensator (STATCOM)
  • 相关文献

同被引文献1

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部