摘要 The article discusses the possibility of a potential reduction in the number of operations of microprocessor relay protection of feeders of the contact network of AC railways TsZA-27.5-FKS (FTS) for unknown reasons. Real statistics on the number of microprocessor relay protection operations at the Buryatskaya traction substation are presented, simulation of the real train situation (in accordance with the regime maps of the throughput capacity of the sections of the Trans-Baikal railway) was carried out in the specialized software complex “KORTES”. Based on the results of the analysis of simulation modeling, the process of forming a unified template of settings using neural network technologies is considered, which characterizes only this specific regular train situation. To protect objects in the event of pre-emergency and emergency modes of operation of the traction power supply system, a variant of changing the standard operation algorithm of the TsZA-27.5-FKS (FTS) terminal by introducing additional blocks for calculating the predictive functions of current and voltage has been proposed. The article discusses the possibility of a potential reduction in the number of operations of microprocessor relay protection of feeders of the contact network of AC railways TsZA-27.5-FKS (FTS) for unknown reasons. Real statistics on the number of microprocessor relay protection operations at the Buryatskaya traction substation are presented, simulation of the real train situation (in accordance with the regime maps of the throughput capacity of the sections of the Trans-Baikal railway) was carried out in the specialized software complex “KORTES”. Based on the results of the analysis of simulation modeling, the process of forming a unified template of settings using neural network technologies is considered, which characterizes only this specific regular train situation. To protect objects in the event of pre-emergency and emergency modes of operation of the traction power supply system, a variant of changing the standard operation algorithm of the TsZA-27.5-FKS (FTS) terminal by introducing additional blocks for calculating the predictive functions of current and voltage has been proposed.
作者 Vostrikov Maksim Viktorovich Daneev Aleksey Vasilyevich Menaker Konstantin Vladimirovich Sizykh Viktor Nikolaevich Vostrikov Maksim Viktorovich;Daneev Aleksey Vasilyevich;Menaker Konstantin Vladimirovich;Sizykh Viktor Nikolaevich(Zabaikalsk Rail Transport Institute, A Branch of Irkutsk State Transport University, Chita, Russia;Irkutsk State Transport University, Irkutsk, Russia)
出处 《Journal of Applied Mathematics and Physics》 2022年第2期491-503,共13页 应用数学与应用物理(英文)
关键词 Automated System MICROPROCESSOR Relay Protection Devices FEEDER Traction Substation Automated System Microprocessor Relay Protection Devices Feeder Traction Substation
  • 相关文献

参考文献1

二级参考文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部