期刊文献+

Return Signal Intensity Ratio Modulates the Impact of Background Signal on Ozone DIAL Night Time Measurement in the Troposphere

Return Signal Intensity Ratio Modulates the Impact of Background Signal on Ozone DIAL Night Time Measurement in the Troposphere
下载PDF
导出
摘要 This paper discusses the uncertainty of ozone differential absorption lidar (DIAL) measurements due to the impact of background signal. The impact of background signal on ozone concentration profiles is proportional to the background intensity and the ratio of return signal intensities at “on” and “off” wavelength ( ) (hereinafter we call it the return signal intensity ratio). Analysis suggests that an appropriate return signal intensity ratio can make the impact of background signal very small, negligible. The simulations based on the analysis coincide with the experimental results. The experimental results show that the impact of background signal is negligible at an appropriate return signal intensity ratio of 0.96 at wavelength pair (280,285 nm). In case of unknown background intensity, we can adjust the laser pulse energy levels at the two wavelengths to obtain an appropriate return signal intensity ratio on the oscilloscope to suppress the impact of background signal and ensure the accuracy of night time ozone measurements. This paper discusses the uncertainty of ozone differential absorption lidar (DIAL) measurements due to the impact of background signal. The impact of background signal on ozone concentration profiles is proportional to the background intensity and the ratio of return signal intensities at “on” and “off” wavelength ( ) (hereinafter we call it the return signal intensity ratio). Analysis suggests that an appropriate return signal intensity ratio can make the impact of background signal very small, negligible. The simulations based on the analysis coincide with the experimental results. The experimental results show that the impact of background signal is negligible at an appropriate return signal intensity ratio of 0.96 at wavelength pair (280,285 nm). In case of unknown background intensity, we can adjust the laser pulse energy levels at the two wavelengths to obtain an appropriate return signal intensity ratio on the oscilloscope to suppress the impact of background signal and ensure the accuracy of night time ozone measurements.
机构地区 不详
出处 《Journal of Electromagnetic Analysis and Applications》 2010年第7期450-456,共7页 电磁分析与应用期刊(英文)
关键词 Differential Absorption LIDAR (DIAL) OZONE Differential Absorption Lidar (DIAL) Ozone

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部