摘要 An active device using electromagnetic forces was constructed and examined for the purpose of minimizing the resonance in air mounts of clean rooms. The air mounts are vulnerable to low-frequency resonance due to heavy weight and low stiffness. A hybrid structure of the active device, composed of pneumatic and electromagnetic parts, was developed and tested. The pneumatic parts in the device support heavy weights under the air mounts, and the electromagnetic parts reduce the resonance. The electromagnetic parts are composed of dual stators and an armature, which surround the pneumatic parts. The resonance can decrease when electromagnetic forces are generated in the gaps between the stators and the armature. Four active devices were installed under a 3-ton surface plate for a vibration test apparatus. The vibration was detected by eddy-current sensors. Discrete P Control logic was based on displacement, and embedded in a C6713 DSP. The results from impact tests show that the peak magnitude in the resonance frequency can be reduced to –10 dB. An active device using electromagnetic forces was constructed and examined for the purpose of minimizing the resonance in air mounts of clean rooms. The air mounts are vulnerable to low-frequency resonance due to heavy weight and low stiffness. A hybrid structure of the active device, composed of pneumatic and electromagnetic parts, was developed and tested. The pneumatic parts in the device support heavy weights under the air mounts, and the electromagnetic parts reduce the resonance. The electromagnetic parts are composed of dual stators and an armature, which surround the pneumatic parts. The resonance can decrease when electromagnetic forces are generated in the gaps between the stators and the armature. Four active devices were installed under a 3-ton surface plate for a vibration test apparatus. The vibration was detected by eddy-current sensors. Discrete P Control logic was based on displacement, and embedded in a C6713 DSP. The results from impact tests show that the peak magnitude in the resonance frequency can be reduced to –10 dB.
出处 《Journal of Electromagnetic Analysis and Applications》 2013年第3期114-119,共6页 电磁分析与应用期刊(英文)
关键词 Low Frequency RESONANCE Active Vibration CONTROL PNEUMATIC Spring AIR MOUNT Low Frequency Resonance Active Vibration Control Pneumatic Spring Air Mount
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部