期刊文献+

Electrical Performance and Effect of Frequency Electromagnetic Waves on Subterranean Termites <i>Coptotermes curvignathus</i>Holmgren

Electrical Performance and Effect of Frequency Electromagnetic Waves on Subterranean Termites <i>Coptotermes curvignathus</i>Holmgren
下载PDF
导出
摘要 The research aimed to propose a non-destructive technology to control subterranean termites Coptotermes curvignathus Holmgren infestation based on electromagnetic waves. A portable apparatus for this technology has been built and its experiment is presented in this paper. Some electrical parameters were measured and analyzed along with their effects to the termites. The experiment using frequency range between 30 Hz - 600 kHz has been done. The average error of the apparatus by comparing the result with the direct measurement using oscilloscope was also measured. The highest error value appeared at 600 kHz with frequency error 6.05 kHz. The highest error of voltage (i.e. 0.186 Volt) appeared at 100 kHz. For safetiness, the highest magnetic field at 300 kHz was 0.1815 μT and at 500 kHz was 0.00725 μT which were safe for human. The average value of termites mortality was higher on irradiation time 120 minutes than 60 minutes respectively in all test frequency: 300 kHz, 400 kHz, 500 kHz and 600 kHz. This paper presents an important information of the electromagnatic-based technology for environmental friendly termites control in spite of using the insecticides. The research aimed to propose a non-destructive technology to control subterranean termites Coptotermes curvignathus Holmgren infestation based on electromagnetic waves. A portable apparatus for this technology has been built and its experiment is presented in this paper. Some electrical parameters were measured and analyzed along with their effects to the termites. The experiment using frequency range between 30 Hz - 600 kHz has been done. The average error of the apparatus by comparing the result with the direct measurement using oscilloscope was also measured. The highest error value appeared at 600 kHz with frequency error 6.05 kHz. The highest error of voltage (i.e. 0.186 Volt) appeared at 100 kHz. For safetiness, the highest magnetic field at 300 kHz was 0.1815 μT and at 500 kHz was 0.00725 μT which were safe for human. The average value of termites mortality was higher on irradiation time 120 minutes than 60 minutes respectively in all test frequency: 300 kHz, 400 kHz, 500 kHz and 600 kHz. This paper presents an important information of the electromagnatic-based technology for environmental friendly termites control in spite of using the insecticides.
出处 《Journal of Electromagnetic Analysis and Applications》 2014年第1期1-7,共7页 电磁分析与应用期刊(英文)
关键词 Electromagnetic Waves FREQUENCY SUBTERRANEAN TERMITES COPTOTERMES curvignathus TERMITES Infestation Electromagnetic Waves Frequency Subterranean Termites Coptotermes curvignathus Termites Infestation
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部