期刊文献+

An Experimental Set-Up for the in Vitro Simulation of a Physiological Pulsatile Flow in the Abdominal Aorta

An Experimental Set-Up for the in Vitro Simulation of a Physiological Pulsatile Flow in the Abdominal Aorta
下载PDF
导出
摘要 In vitro experimental set-up is an important tool for investigating abdominal aortic aneurysm (AAA). Accurate reproduction of the physiological pulsatile flow waveform in the abdominal aorta at various anatomic locations is an important component of these experimental methods. The objective of this study is to establish an experimental set-up to generate a physiological pulsatile flow for in vitro simulations of the abdominal aorta. The physiological flow was established by a computer-controlled peristaltic pump and the flow field in a circular straight pipe is measured under pulsatile flow conditions by a 2-dimensional particle image velocimetry system (2D-PIV). Experimental results show that the in vitro experimental set-up provides a flow with a period of 2 s, a reasonable cross-sectional velocity distribution and an approximate inlet velocity profile that is close to the human abdominal aorta. In vitro experimental set-up is an important tool for investigating abdominal aortic aneurysm (AAA). Accurate reproduction of the physiological pulsatile flow waveform in the abdominal aorta at various anatomic locations is an important component of these experimental methods. The objective of this study is to establish an experimental set-up to generate a physiological pulsatile flow for in vitro simulations of the abdominal aorta. The physiological flow was established by a computer-controlled peristaltic pump and the flow field in a circular straight pipe is measured under pulsatile flow conditions by a 2-dimensional particle image velocimetry system (2D-PIV). Experimental results show that the in vitro experimental set-up provides a flow with a period of 2 s, a reasonable cross-sectional velocity distribution and an approximate inlet velocity profile that is close to the human abdominal aorta.
作者 Tiandong Lu Jiemin Zhan Wei Su Wenqing Hu Tiandong Lu;Jiemin Zhan;Wei Su;Wenqing Hu(Department of Applied Mechanics and Engineering, School of Aeronautics and Astronautics, Sun Yat-sen University, Guangzhou, China)
出处 《Journal of Flow Control, Measurement & Visualization》 CAS 2022年第4期148-160,共13页 流量控制、测量及可视化(英文)
关键词 2-Dimensional Particle Image Velocimetry System Abdominal Aorta Blood-Flow Experimental Set-Up Flow Field 2-Dimensional Particle Image Velocimetry System Abdominal Aorta Blood-Flow Experimental Set-Up Flow Field
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部