Preliminary Tests of a Kerma-Area Product (KAP) Meter to Be Used as a Monitor Chamber in a Conventional Diagnostic X Ray System

Preliminary Tests of a Kerma-Area Product (KAP) Meter to Be Used as a Monitor Chamber in a Conventional Diagnostic X Ray System
下载PDF
导出
摘要 This study presents the results of the preliminary tests performed using a kerma-area product (KAP) meter in order to verify its usefulness as a monitor chamber in a clinical X ray system, which will be used in ionization chambers’ quality control program. The tests performed were repeatability, surface measurement uniformity, linearity with tube current, measurement variation changing the distance and field size, KAP chamber radiation attenuation, and energy dependence. The KAP meter has presented a good repeatability (a maximum variation of 0.4%);its surface has a homogeneous response (a maximum variation of 1.0% among the different irradiated regions);the response is linear with the tube current and the variation of the PKA along the distance is less than 3.43%. On the other hand, the results obtained for chamber attenuation and energy dependence show that some corrections must be applied when the measurements are made. The results have shown a good performance of the KAP meter, confirming that it is possible to use this instrument as a monitor chamber. However, it is important to highlight that some correction factors for energy dependence and chamber radiation attenuation must be considered. This study presents the results of the preliminary tests performed using a kerma-area product (KAP) meter in order to verify its usefulness as a monitor chamber in a clinical X ray system, which will be used in ionization chambers’ quality control program. The tests performed were repeatability, surface measurement uniformity, linearity with tube current, measurement variation changing the distance and field size, KAP chamber radiation attenuation, and energy dependence. The KAP meter has presented a good repeatability (a maximum variation of 0.4%);its surface has a homogeneous response (a maximum variation of 1.0% among the different irradiated regions);the response is linear with the tube current and the variation of the PKA along the distance is less than 3.43%. On the other hand, the results obtained for chamber attenuation and energy dependence show that some corrections must be applied when the measurements are made. The results have shown a good performance of the KAP meter, confirming that it is possible to use this instrument as a monitor chamber. However, it is important to highlight that some correction factors for energy dependence and chamber radiation attenuation must be considered.
出处 《Journal of Modern Physics》 2015年第4期483-489,共7页 现代物理(英文)
关键词 KAP METER Quality Control DIAGNOSTIC RADIOLOGY MONITOR CHAMBER KAP Meter Quality Control Diagnostic Radiology Monitor Chamber
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部