期刊文献+

Toward a Test Protocol for Conducted Energy Weapons

Toward a Test Protocol for Conducted Energy Weapons
下载PDF
导出
摘要 Conducted Energy Weapons (CEWs), such as those manufactured by TASER International Inc., are seeing increased use by law enforcement agencies as a less lethal force option;but, at the same time, these weapons are also seeing an increased level of concern in terms of their safety of use. In order to enable consistent evaluation of CEW performance, a systematic protocol for testing the electrical output of such weapons is required. In this paper, we propose a test specification for CEWs, designed to calculate the key performance and electrical safety parameters. The weapon is fired into a specified load, and current or voltage data are acquired, from which a set of electrical parameters are calculated and recorded. The protocol is based on experience of testing 6000 CEWs in the labs affiliated with the authors. This test protocol is designed to enable systematic testing, evaluation and research on CEW’s, including identification of weapons which are out of specification, determination of changes in weapon characteristics over time, and evaluation of weapons post-incident. Based on the proposed test protocol, we evaluate and report on electrical output produced by 208 X26TM and128 M26TM TASER? weapons. Results are shown in terms of proposed summary parameters and in terms of manufacturer’s performance specifications. Conducted Energy Weapons (CEWs), such as those manufactured by TASER International Inc., are seeing increased use by law enforcement agencies as a less lethal force option;but, at the same time, these weapons are also seeing an increased level of concern in terms of their safety of use. In order to enable consistent evaluation of CEW performance, a systematic protocol for testing the electrical output of such weapons is required. In this paper, we propose a test specification for CEWs, designed to calculate the key performance and electrical safety parameters. The weapon is fired into a specified load, and current or voltage data are acquired, from which a set of electrical parameters are calculated and recorded. The protocol is based on experience of testing 6000 CEWs in the labs affiliated with the authors. This test protocol is designed to enable systematic testing, evaluation and research on CEW’s, including identification of weapons which are out of specification, determination of changes in weapon characteristics over time, and evaluation of weapons post-incident. Based on the proposed test protocol, we evaluate and report on electrical output produced by 208 X26TM and128 M26TM TASER? weapons. Results are shown in terms of proposed summary parameters and in terms of manufacturer’s performance specifications.
出处 《Modern Instrumentation》 2013年第1期7-15,共9页 现代仪器(英文)
关键词 Conducted ENERGY Weapons ELECTRICAL STIMULATION Electrophysiological STANDARDS Conducted Energy Weapons Electrical Stimulation Electrophysiological Standards
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部