Partial Quality Assessment of <sup>60</sup>Co-Teletherapy Machine Performance

Partial Quality Assessment of <sup>60</sup>Co-Teletherapy Machine Performance
下载PDF
导出
摘要 The aim of this study was to assess the performance of 60Co-teletherapy unit at Radiation and Isotopes Center in Khartoum, using the common tools used for quality control (Front pointer, Graphic paper, Pin, Non-screen film, meter and Check plate). The collected and analyzed data revealed that: there was a difference between the calculated theoretical field size (FS) and the measured one relative to the change of SSD;and the average FS shift was 0.9 cm relative to the standard one, while the machine isocenter was almost fixed at 0° with a shift of 0.003 cm, which was within the standard limit (0.2 cm). The diaphragm isocenter showed a shift of ±0.36 cm (i.e. in clock and anti clock wise) in average relative to standard limit (±0.3 cm) and the couch vertical isocenter (CVI) relative to the SSD changes was exceeded the standard limit (0.2 cm) by a factor of 0.9 cm. Also the SSD determined by the optical distance indicator was greater than the actual SSD (determined by Front pointer and measured by scale meter) by an average of 0.8 cm;which exceeded the limit (0.3 cm) by an average factor of 0.5 cm. The study also showed that the penumbra profile (1.5 cm) was less than the actual specified for 60Co-teletherapy machine, while the radiation beam was so homogeneous across the field size. The aim of this study was to assess the performance of 60Co-teletherapy unit at Radiation and Isotopes Center in Khartoum, using the common tools used for quality control (Front pointer, Graphic paper, Pin, Non-screen film, meter and Check plate). The collected and analyzed data revealed that: there was a difference between the calculated theoretical field size (FS) and the measured one relative to the change of SSD;and the average FS shift was 0.9 cm relative to the standard one, while the machine isocenter was almost fixed at 0° with a shift of 0.003 cm, which was within the standard limit (0.2 cm). The diaphragm isocenter showed a shift of ±0.36 cm (i.e. in clock and anti clock wise) in average relative to standard limit (±0.3 cm) and the couch vertical isocenter (CVI) relative to the SSD changes was exceeded the standard limit (0.2 cm) by a factor of 0.9 cm. Also the SSD determined by the optical distance indicator was greater than the actual SSD (determined by Front pointer and measured by scale meter) by an average of 0.8 cm;which exceeded the limit (0.3 cm) by an average factor of 0.5 cm. The study also showed that the penumbra profile (1.5 cm) was less than the actual specified for 60Co-teletherapy machine, while the radiation beam was so homogeneous across the field size.
出处 《Open Journal of Radiology》 2015年第4期235-242,共8页 放射学期刊(英文)
关键词 60Co-Quality CONTROL Teletherapy RADIOTHERAPY ASSURANCE 60Co-Quality Control Teletherapy Radiotherapy Assurance
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部