期刊文献+

Porous Silicon as Soft Material in Low-Frequency MEMS (MicroElectro-Mechanical Systems) Resonators

Porous Silicon as Soft Material in Low-Frequency MEMS (MicroElectro-Mechanical Systems) Resonators
下载PDF
导出
摘要 This study focuses on the mechanical response of silicon on porous silicon bilayer cantilevers ended with a seismic mass. The porous silicon is intended to provide an alternative to decrease the cantilever stiffness for low-frequency MEMS applications. The first eigenfrequency of the cantilever is obtained using static deflection obtained under classical Euler-Bernoulli assumptions and Rayleigh method. In order to estimate the errors due to small-strain approximation and Euler-Bernoulli theory, the analytical results were validated through 3D finite element simulations for different cantilever geometries and porosities. Both bulk silicon and silicon on porous silicon bilayer cantilevers ended with a seismic mass were fabricated and we measured the first eigenfrequency (f0) and quality factor (Q) by using a laser Doppler vibrometer. In agreement with the theoretical predictions we found that, when compared to bulk silicon cantilevers, the first eigenfrequency of a bilayer cantilever containing 6% porous silicon (at 50% porosity) on 94% bulk silicon is lowered by 5%, from (5447 ±120) Hz to ≈5198 Hz. This decrease is also accompanied by a reduction of the quality factor by two. This study focuses on the mechanical response of silicon on porous silicon bilayer cantilevers ended with a seismic mass. The porous silicon is intended to provide an alternative to decrease the cantilever stiffness for low-frequency MEMS applications. The first eigenfrequency of the cantilever is obtained using static deflection obtained under classical Euler-Bernoulli assumptions and Rayleigh method. In order to estimate the errors due to small-strain approximation and Euler-Bernoulli theory, the analytical results were validated through 3D finite element simulations for different cantilever geometries and porosities. Both bulk silicon and silicon on porous silicon bilayer cantilevers ended with a seismic mass were fabricated and we measured the first eigenfrequency (f0) and quality factor (Q) by using a laser Doppler vibrometer. In agreement with the theoretical predictions we found that, when compared to bulk silicon cantilevers, the first eigenfrequency of a bilayer cantilever containing 6% porous silicon (at 50% porosity) on 94% bulk silicon is lowered by 5%, from (5447 ±120) Hz to ≈5198 Hz. This decrease is also accompanied by a reduction of the quality factor by two.
出处 《World Journal of Mechanics》 2018年第11期431-443,共13页 力学国际期刊(英文)
关键词 POROUS Silicon CANTILEVER RESONATOR Porous Silicon Cantilever Resonator
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部