期刊文献+

An Approach for Using of Poly Glycolic Acid (PGA) in Reference Standard Dosimetry: PGA/ESR Dosimetry System Response Curve and Post Irradiation Stability

An Approach for Using of Poly Glycolic Acid (PGA) in Reference Standard Dosimetry: PGA/ESR Dosimetry System Response Curve and Post Irradiation Stability
下载PDF
导出
摘要 Reference Standard Dosimeters are used to calibrate radiation environments and routine dosimeters. It can also be used in routine dosimetry applications for radiation processing where higher quality dosimetry measurements are required. Electron Spin Resonance (ESR) is a well-established Reference Standard Dosimetry system in industrial applications of ionising radiation, and its use is also proposed in radiation therapy and accident dosimetry. In the present experimental work, PGA solid state dosimeter (SSD) has been investigated using ESR spectroscopy to study the gamma radiation response of this material and to evaluate its dosimetric characteristics: dose response, room temperature fading, heat treatment effect during post-irradiation storage. Results obtained up to now confirm that PGA seems to be suitable material for ESR dosimetry applications. Reference Standard Dosimeters are used to calibrate radiation environments and routine dosimeters. It can also be used in routine dosimetry applications for radiation processing where higher quality dosimetry measurements are required. Electron Spin Resonance (ESR) is a well-established Reference Standard Dosimetry system in industrial applications of ionising radiation, and its use is also proposed in radiation therapy and accident dosimetry. In the present experimental work, PGA solid state dosimeter (SSD) has been investigated using ESR spectroscopy to study the gamma radiation response of this material and to evaluate its dosimetric characteristics: dose response, room temperature fading, heat treatment effect during post-irradiation storage. Results obtained up to now confirm that PGA seems to be suitable material for ESR dosimetry applications.
出处 《World Journal of Nuclear Science and Technology》 2012年第3期73-79,共7页 核科学与技术国际期刊(英文)
关键词 DOSIMETRY Solid State Dosimeter (SSD) POLY Glycolic Acid (PGA) Electron Spin Resonance (ESR) Reference Standard Dosimetery Post-Irradiation Thermal Treatments Fading Behaviour Dosimetry Solid State Dosimeter (SSD) Poly Glycolic Acid (PGA) Electron Spin Resonance (ESR) Reference Standard Dosimetery Post-Irradiation Thermal Treatments Fading Behaviour
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部