摘要 The real-time monitoring of environmental radiation dose for nuclear fa-cilities is an important part of safety, in order to guarantee the accuracy of the monitoring results regular calibration is necessary. Around nuclear facilities there are so many environmental dosimeters installed dispers-edly, because of its huge quantity, widely distributed, and in real-time monitoring state;it will cost lots of manpower and finance if it were tak-en to calibrate on standard laboratory;what’s more it will make the en-vironment out of control. To solve the problem of the measurement ac-curacy of the stationary gamma radiation dosimeter, an on-site calibra-tion method is proposed. The radioactive source is X-ray spectrum, and the dose reference instrument which has been calibrated by the national standard laboratory is a high pressure ionization. On-site calibration is divided into two parts;firstly the energy response experiment of dosim-eter for high and low energy is done in the laboratory, and the energy response curve is obtained combining with Monte Carlo simulation;sec-ondly experiment is carried out in the field of the measuring dosimeter, and the substitution method to calibrate the dosimeter is used;finally the calibration coefficient is gotten through energy curve correction. In order to verify the accuracy of on-site calibration method, the calibrated dosimeter is test in the standard laboratory and the error is 3.4%. The re-sult shows that the on-site calibration method using X-ray is feasible, and it can improves the accuracy of the measurement results of the stationary γ-ray instrument;what’s more important is that it has great reference value for the radiation safety management and radiation environment evaluation. The real-time monitoring of environmental radiation dose for nuclear fa-cilities is an important part of safety, in order to guarantee the accuracy of the monitoring results regular calibration is necessary. Around nuclear facilities there are so many environmental dosimeters installed dispers-edly, because of its huge quantity, widely distributed, and in real-time monitoring state;it will cost lots of manpower and finance if it were tak-en to calibrate on standard laboratory;what’s more it will make the en-vironment out of control. To solve the problem of the measurement ac-curacy of the stationary gamma radiation dosimeter, an on-site calibra-tion method is proposed. The radioactive source is X-ray spectrum, and the dose reference instrument which has been calibrated by the national standard laboratory is a high pressure ionization. On-site calibration is divided into two parts;firstly the energy response experiment of dosim-eter for high and low energy is done in the laboratory, and the energy response curve is obtained combining with Monte Carlo simulation;sec-ondly experiment is carried out in the field of the measuring dosimeter, and the substitution method to calibrate the dosimeter is used;finally the calibration coefficient is gotten through energy curve correction. In order to verify the accuracy of on-site calibration method, the calibrated dosimeter is test in the standard laboratory and the error is 3.4%. The re-sult shows that the on-site calibration method using X-ray is feasible, and it can improves the accuracy of the measurement results of the stationary γ-ray instrument;what’s more important is that it has great reference value for the radiation safety management and radiation environment evaluation.
出处 《World Journal of Nuclear Science and Technology》 2017年第2期93-102,共10页 核科学与技术国际期刊(英文)
关键词 X RAY SOURCE ON-SITE Calibration Energy Response GAMMA RADIATION DOSIMETER X Ray Source On-Site Calibration Energy Response Gamma Radiation Dosimeter
  • 相关文献

参考文献5

二级参考文献37

  • 1于水,王功鹏,关守任.低大气层宇宙射线剂量水平及机组人员受照剂量的研究[J].辐射防护,1997,17(2):103-108. 被引量:7
  • 2岳清宇,金花.低大气层中宇宙射线电离量的分布测量[J].辐射防护,1988,8(6):401-409.
  • 3高飞.Co-60、Cs-137光子参考辐射场中散射辐射问题的蒙卡方法研究[D].北京:中国原子能科学研究院,2009.
  • 4Health and Sa{ety Laboratory. High pressure ar- gon ionization chamber systems for the measure- ment of environmental radiation exposure rates [R]. New York: HASL260, 1972.
  • 5任天山,林莲卿,陈志鹏.宇宙射线电离量的测定和几种探测器对宇宙射线的响应[J].辐射防护,1987,7(3):185-190.
  • 6International Organization for Standardization. X and gamma reference radiations for calibrating dose- meters and dose rate meters and for determining their response as a function of photon energy, Part 1: Radiation characteristics and production method [S]. Geneva: ISO Publication Office, 1997.
  • 7全国核能标准化技术委员会.GB/T12162.1-2000用于校准剂量仪和剂量率仪及确定其能量响应的x和Y参考辐射,第一部分:辐射特性及产生方法[s].北京:中国标准出版社,2000.
  • 8de PLANQUE G, GESELL T F. Environmental measurements with thermoluminescence doseme- ters-trends and issues[J]. Radiation Protection Dosimetry, 1986, 17: 193-200.
  • 9MAIELLO M L G. 8'h international intercompar- ison of environmental dosemeters[J]. Radiation Protection Dosimetry, 1990, 32: 91-98.
  • 10MAIELLO M L G. Ninth international 'mini' intereomparison of environmental dosemeters: A further analysis of the data[J], Radiation Protec- tion Dosimetry, 1995, 58: 167-175.