期刊文献+

Sub-Criticality Measurement with Source Term for Research Reactor in Inverse Kinetics Method 被引量:1

Sub-Criticality Measurement with Source Term for Research Reactor in Inverse Kinetics Method
下载PDF
导出
摘要 In reactor physics tests, it is important to monitor sub-criticality continuously during criticality approach. Reactivity measurements by the inverse kinetics method are widely used during the operation of a nuclear reactor. This technique is successfully applied at sufficiently high power level or to a core without an external neutron source where the neutron source term in point reactor kinetics equations may be neglected. For operation at low power levels or in the sub-critical domain, the increase in the fluctuation of the neutron signal may cause difficulties in the evaluation of reactivity and the effect of direct emission from the external neutron source may not be neglected. Therefore, contribution of the neutron source must be taken into account and this implies knowledge of a quantity proportional to the source strength, which calls the source term and then it should be determined. The research work has been conducted to measure reactivity with source term using a dedicated reactivity measurement system by the Least Square Inverse Kinetics Method (LSIKM). Application to a simulator of HANARO research reactor, Korea Atomic Energy Research Institute (KAERI), with known source strength and reactivity worth has showed consistent and satisfactory agreement. In reactor physics tests, it is important to monitor sub-criticality continuously during criticality approach. Reactivity measurements by the inverse kinetics method are widely used during the operation of a nuclear reactor. This technique is successfully applied at sufficiently high power level or to a core without an external neutron source where the neutron source term in point reactor kinetics equations may be neglected. For operation at low power levels or in the sub-critical domain, the increase in the fluctuation of the neutron signal may cause difficulties in the evaluation of reactivity and the effect of direct emission from the external neutron source may not be neglected. Therefore, contribution of the neutron source must be taken into account and this implies knowledge of a quantity proportional to the source strength, which calls the source term and then it should be determined. The research work has been conducted to measure reactivity with source term using a dedicated reactivity measurement system by the Least Square Inverse Kinetics Method (LSIKM). Application to a simulator of HANARO research reactor, Korea Atomic Energy Research Institute (KAERI), with known source strength and reactivity worth has showed consistent and satisfactory agreement.
出处 《World Journal of Nuclear Science and Technology》 2017年第3期129-135,共7页 核科学与技术国际期刊(英文)
关键词 Source Strength Sub-Critical REACTIVITY REACTOR KINETICS INVERSE KINETICS Method Source Strength Sub-Critical Reactivity Reactor Kinetics Inverse Kinetics Method
  • 相关文献

同被引文献6

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部