期刊文献+

Modification of water application uniformity among closed circuit trickle irrigation systems

Modification of water application uniformity among closed circuit trickle irrigation systems
下载PDF
导出
摘要 The aim of this research was determine the ma- ximum application uniformity of closed circuit trickle irrigation systems designs. Laboratory tests carried out for Two types of closed circuits: a) One manifold for lateral lines or Closed circuits with One Manifold of Trikle Irrigation System (COMTIS);b) Closed circuits with Two Manifolds of Trikle Irrigation System (CTMTIS), and c) Traditional Trikle Irrigation System (TTIS) as a control. Three lengths of lateral lines were used, 40, 60, and 80 meters. PE tubes lateral lines: 16 mm diameter;30 cm emitters distance, and GR built-in emitters 4 lph when operating pressure 1 bar. Experiments were conducted at the Agric. Eng. Res. Inst., ARC, MALR, Egypt. With COMTIS the emitter flow rate was 4.07, 3.51, and 3.59 lph compared to 4.18, 3.72, and 3.71 lph with CTMTIS and 3.21, 2.6, and 2.16 lph with TTIS (lateral lengths 40, 60, and 80 meters respectively). Uniformity varied widely within individual lateral lengths and between circuit types. Under CTMTIS uniformity values were 97.74, 95.14, and 92.03 %;with COMTIS they were 95.73, 89.45, and 83.25 %;and with TTIS they were 88.27, 84.73, and 80.53 % (for lateral lengths 40, 60, 80 meters respectively). The greatest uniformity was observed under CTMTIS and COMTIS when using the shortest lateral length 40 meters, then lateral length 60 meters, while the lowest value was observed when using lateral length 80 meters this result depends on the physical and hydraulic characteristics of the emitter and lateral line. CTMTIS was more uniform than either COMTIS or TTIS. Friction losses were decreased with CTMTIS in the emitter laterals at lengths 40 meters compared to TTIS and COMTIS. Therefore, differences may be related to increased friction losses when using TDIS and COMDIS. The aim of this research was determine the ma- ximum application uniformity of closed circuit trickle irrigation systems designs. Laboratory tests carried out for Two types of closed circuits: a) One manifold for lateral lines or Closed circuits with One Manifold of Trikle Irrigation System (COMTIS);b) Closed circuits with Two Manifolds of Trikle Irrigation System (CTMTIS), and c) Traditional Trikle Irrigation System (TTIS) as a control. Three lengths of lateral lines were used, 40, 60, and 80 meters. PE tubes lateral lines: 16 mm diameter;30 cm emitters distance, and GR built-in emitters 4 lph when operating pressure 1 bar. Experiments were conducted at the Agric. Eng. Res. Inst., ARC, MALR, Egypt. With COMTIS the emitter flow rate was 4.07, 3.51, and 3.59 lph compared to 4.18, 3.72, and 3.71 lph with CTMTIS and 3.21, 2.6, and 2.16 lph with TTIS (lateral lengths 40, 60, and 80 meters respectively). Uniformity varied widely within individual lateral lengths and between circuit types. Under CTMTIS uniformity values were 97.74, 95.14, and 92.03 %;with COMTIS they were 95.73, 89.45, and 83.25 %;and with TTIS they were 88.27, 84.73, and 80.53 % (for lateral lengths 40, 60, 80 meters respectively). The greatest uniformity was observed under CTMTIS and COMTIS when using the shortest lateral length 40 meters, then lateral length 60 meters, while the lowest value was observed when using lateral length 80 meters this result depends on the physical and hydraulic characteristics of the emitter and lateral line. CTMTIS was more uniform than either COMTIS or TTIS. Friction losses were decreased with CTMTIS in the emitter laterals at lengths 40 meters compared to TTIS and COMTIS. Therefore, differences may be related to increased friction losses when using TDIS and COMDIS.
机构地区 不详
出处 《Agricultural Sciences》 2010年第1期1-9,共9页 农业科学(英文)
关键词 Trickle IRRIGATION CLOSED CIRCUITS MANIFOLD LATERAL Flow Rate UNIFORMITY Trickle Irrigation Closed Circuits Manifold Lateral Flow Rate Uniformity
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部