期刊文献+

Relationship between Atmospheric CO<sub>2</sub>Concentration and Vegetation in a Hospital Area: The Policlinico Umberto I in Rome

Relationship between Atmospheric CO<sub>2</sub>Concentration and Vegetation in a Hospital Area: The Policlinico Umberto I in Rome
下载PDF
导出
摘要 The capability of the plants growing in the Policlinico Umberto I, one of the most important hospitals in Rome, to lower carbon dioxide (CO2) and air temperature was analyzed. The CO2 concentration inside and outside the hospital and traffic density in the streets surrounding the area was monitored monthly. Measurements of structural plant traits were carried out. The highest CO2 concentration was monitored in winter-spring (425 ± 8 ppm, mean value) when traffic density peaks, decreasing by 17% in summer. During the day-time, the highest CO2 concentration (433 ± 61 ppm, mean value) was measured in the first hours of the morning (9:00) decreasing by 12% from 11.00 to 13.00 in relationship with traffic density decreasing (p 0.05). Among the greening present in the hospital area, the “group of trees” plays an important role in lowering CO2 concentration compared to meadows. Moreover, outside the Policlinico air temperature was, on average, 17% higher compared to the inside. The results show the effectiveness of plants in improving air quality and suggest that greening traits may be used to realise an inventory available for tree planting programs to ameliorate the quality of life. The capability of the plants growing in the Policlinico Umberto I, one of the most important hospitals in Rome, to lower carbon dioxide (CO2) and air temperature was analyzed. The CO2 concentration inside and outside the hospital and traffic density in the streets surrounding the area was monitored monthly. Measurements of structural plant traits were carried out. The highest CO2 concentration was monitored in winter-spring (425 ± 8 ppm, mean value) when traffic density peaks, decreasing by 17% in summer. During the day-time, the highest CO2 concentration (433 ± 61 ppm, mean value) was measured in the first hours of the morning (9:00) decreasing by 12% from 11.00 to 13.00 in relationship with traffic density decreasing (p 0.05). Among the greening present in the hospital area, the “group of trees” plays an important role in lowering CO2 concentration compared to meadows. Moreover, outside the Policlinico air temperature was, on average, 17% higher compared to the inside. The results show the effectiveness of plants in improving air quality and suggest that greening traits may be used to realise an inventory available for tree planting programs to ameliorate the quality of life.
出处 《American Journal of Plant Sciences》 2019年第8期1313-1324,共12页 美国植物学期刊(英文)
关键词 CO2 CONCENTRATION HOSPITAL Air Temperature Green COVER CO2 Concentration Hospital Air Temperature Green Cover
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部