Analysis of trans tibial prosthetic socket materials using finite element method

Analysis of trans tibial prosthetic socket materials using finite element method
下载PDF
导出
摘要 The objective of this work was to analyze in a parametric study for optimum design solution of prosthetic socket material by finite element method. A realistic three-dimensional finite element model of the PTB socket was developed to find out the stress distribution pattern under physiologically relevant loading condition during normal walking. The CAD model of the rectified socket was collected from a CMET 250 non-tactile high accuracy (0.06 mm) white light scanner and analyses were carried out using finite element Method in ANSYS?. All structural materials used in the analysis were assumed to be linearly elastic, homogeneous and isotropic. Different materials were used for socket and only polypropylene was used for socket adopter. Analysis was prepared at 2 mm, 3 mm, 4 mm, 5 mm & 6 mm thickness of socket in different materials commonly used in developing countries. The bottom line of socket was made to zero displacement constraints and vertical loads in relation to stance phase of gait cycle were applied under static condition at the patella tendon brim. The 3 mm laminated composite sockets was found to be optimum in terms of strength, weight and factor of safety. The objective of this work was to analyze in a parametric study for optimum design solution of prosthetic socket material by finite element method. A realistic three-dimensional finite element model of the PTB socket was developed to find out the stress distribution pattern under physiologically relevant loading condition during normal walking. The CAD model of the rectified socket was collected from a CMET 250 non-tactile high accuracy (0.06 mm) white light scanner and analyses were carried out using finite element Method in ANSYS?. All structural materials used in the analysis were assumed to be linearly elastic, homogeneous and isotropic. Different materials were used for socket and only polypropylene was used for socket adopter. Analysis was prepared at 2 mm, 3 mm, 4 mm, 5 mm & 6 mm thickness of socket in different materials commonly used in developing countries. The bottom line of socket was made to zero displacement constraints and vertical loads in relation to stance phase of gait cycle were applied under static condition at the patella tendon brim. The 3 mm laminated composite sockets was found to be optimum in terms of strength, weight and factor of safety.
机构地区 不详
出处 《Journal of Biomedical Science and Engineering》 2011年第12期762-768,共7页 生物医学工程(英文)
关键词 FINITE Element Method TRANSTIBIAL PROSTHESIS SOCKET Polymer Finite Element Method Transtibial Prosthesis Socket Polymer
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部