期刊文献+

Electromyography Control of a Computer Model of the Arm

Electromyography Control of a Computer Model of the Arm
下载PDF
导出
摘要 Human arm movements may be adversely affected in the event of stroke or spinal cord injuries, eventually causing the patient to lose control of arm movements. Electromyography (EMG) is con-sidered the most effective technique for the restoration of arm movement in such cases. The reha-bilitation period for such patients is usually long. Moreover, complex treatment techniques may demoralize them. Therefore, this study, attempts to contribute to the development of a relaxing rehabilitation environment through electromyography control of a computer model of the arm. The model is created using MATLAB? and Data LINK software and other requisite components for training the targeted participants to control their arm movements. Six male participants with no history of injury to the arms or back were selected using the set protocol. The results and data collected are analysed using three performance measures i.e. the number of target hits, average time to target, and path efficiency for each target. Then, the main results in terms of the obtained performance measures are discussed and compared with those of previous studies. Human arm movements may be adversely affected in the event of stroke or spinal cord injuries, eventually causing the patient to lose control of arm movements. Electromyography (EMG) is con-sidered the most effective technique for the restoration of arm movement in such cases. The reha-bilitation period for such patients is usually long. Moreover, complex treatment techniques may demoralize them. Therefore, this study, attempts to contribute to the development of a relaxing rehabilitation environment through electromyography control of a computer model of the arm. The model is created using MATLAB? and Data LINK software and other requisite components for training the targeted participants to control their arm movements. Six male participants with no history of injury to the arms or back were selected using the set protocol. The results and data collected are analysed using three performance measures i.e. the number of target hits, average time to target, and path efficiency for each target. Then, the main results in terms of the obtained performance measures are discussed and compared with those of previous studies.
出处 《Journal of Biomedical Science and Engineering》 2014年第13期1038-1048,共11页 生物医学工程(英文)
关键词 ELECTROMYOGRAPHY (EMG) Signals HUMAN ARM Movements MUSCLE CONTROL HUMAN ARM Model Electromyography (EMG) Signals Human Arm Movements Muscle Control Human Arm Model
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部