Design, Realization and Implementation of a Novel Phantom for Quality Control of Micro-SPECT/CT and Micro-PET/CT Systems

Design, Realization and Implementation of a Novel Phantom for Quality Control of Micro-SPECT/CT and Micro-PET/CT Systems
下载PDF
导出
摘要 The proposed phantom is designed for the quality control of micro-SPECT/CT and micro-PET/CT systems. However, it is an assembly of six patterns stored in a cylindrical box enabling to control both micro-SPECT unit in terms of uniformity, spatial linearity and spatial resolution and micro-CT unit in terms of uniformity, spatial linearity, spatial resolution, diffusion rate, low contrast detectability, Hounsfield unit linearity and slice thickness. The construction material is Plexiglas. As for the implementation, it was made on a micro-SPECT/CT machine of the type “speCZT eXplore CT 120”. Compared to the NEMA NU 4-2008 image quality phantom, this phantom offers micro-CT quality control and is more efficient in control of spatial resolution for micro-SPECT and micro- PET systems. The proposed phantom is designed for the quality control of micro-SPECT/CT and micro-PET/CT systems. However, it is an assembly of six patterns stored in a cylindrical box enabling to control both micro-SPECT unit in terms of uniformity, spatial linearity and spatial resolution and micro-CT unit in terms of uniformity, spatial linearity, spatial resolution, diffusion rate, low contrast detectability, Hounsfield unit linearity and slice thickness. The construction material is Plexiglas. As for the implementation, it was made on a micro-SPECT/CT machine of the type “speCZT eXplore CT 120”. Compared to the NEMA NU 4-2008 image quality phantom, this phantom offers micro-CT quality control and is more efficient in control of spatial resolution for micro-SPECT and micro- PET systems.
出处 《Journal of Biomedical Science and Engineering》 2015年第1期46-55,共10页 生物医学工程(英文)
关键词 PHANTOM Quality Control Micro-SPECT/CT Micro-PET/CT Phantom Quality Control Micro-SPECT/CT Micro-PET/CT
  • 相关文献

参考文献1

二级参考文献8

  • 1Sandberg C,Holmes J,McCoy K,et al.The application of a continuous leak detection system to pipeline and associated equipment.IEEE Transaction on Industry Application,1989,25(5):906-909.
  • 2Furenlid L R,Wilson D W,Chert Y C.FastSPECT II:A second-generation high-resolution dynamic SPECT imager.IEEE Transactions on Nuclear Science,2004,51(3):631-635.
  • 3Beckman F J,van der Have F,Vastenhouw B,et al.U-SPECT-I:A stationary molecular imaging system for small animals with 0.1 micro-litre resolution.In:Proceedings of IEEE Nuclear Science Symposium Conference.2004,4:2263-2267.
  • 4Hsiao I T,Rangarajan A,Gindi G R.A new convergent map reconstruction algorithm for emission tomography using ordered subsets and separable surrogates.In:Proceedings of IEEE International Symposium on Biomedical Imaging.Washington,USA,2002:409-412.
  • 5Hsieh H H,Hsiao I T,Lin K J.Analytic calculation of multi-pinhole collimator sensitivity with tilted pinholes.In:Proceedings of IEEE Nuclear Science Symposium Conference.Dresden,Germany,2008:4724-4727.
  • 6Cherry S R,Sorenson J A,Phelps M C.Physics in Nuclear Medicine.3rd Ed.Philadelphia:Saunders,2003.
  • 7Kao C M,Sidky E Y,Pan X C.Precise imaging of small animals using a dnal-bead microPET scanner.Medical Imaging,2006,6143:614303-1-614303-6.
  • 8Sidky E Y,Kao C M,Pan X C.Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT.Journal of X-Ray Science and Technology,2006,14:119-139.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部