期刊文献+

Methods to Minimize Optical Noise That Degrade Fluorescence Efficiency of Optical Probe for Near-Infrared Tracking in Surgical Environment

Methods to Minimize Optical Noise That Degrade Fluorescence Efficiency of Optical Probe for Near-Infrared Tracking in Surgical Environment
下载PDF
导出
摘要 In the medical field, there are growing interests in applied research such as in vivo fluorescence monitoring because of excellent body transmission characteristic of the near-infrared light. However, optical noise by excitation light and illumination equipment for medical applications such as interior light, surgical light decrease efficiency of the fluorescent signal when observers such as surgeons confirm fluorescence signals in medical field. To solve these problems in medical field, we have analyzed external noise factors by effect on image realization, quantification of optical noise generation by external factors, and have suggested methods of minimize the optical noise in this paper. In case of fluorescence imaging in the operating room, it has been confirmed that fluorescent excitation light, interior light and surgical light are factors to generate optical noise. To acquire near-infrared fluorescence images and to compare fluorescence contrast under conditions of darkroom, interior light and surgical light, light emitting diodes (LEDs) sources that have peak wavelength at 740, 760 and 780 nm respectively were used as excitation light sources. In addition, short-pass filter which has transmission edge at 775 nm has been applied to minimize the optical noise in each external noise factor. By comparing contrast of each image before and after use of the short-pass filter, we confirmed that optical noise reduced 49%, 56% and 66% in external noise factors respectively. In the medical field, there are growing interests in applied research such as in vivo fluorescence monitoring because of excellent body transmission characteristic of the near-infrared light. However, optical noise by excitation light and illumination equipment for medical applications such as interior light, surgical light decrease efficiency of the fluorescent signal when observers such as surgeons confirm fluorescence signals in medical field. To solve these problems in medical field, we have analyzed external noise factors by effect on image realization, quantification of optical noise generation by external factors, and have suggested methods of minimize the optical noise in this paper. In case of fluorescence imaging in the operating room, it has been confirmed that fluorescent excitation light, interior light and surgical light are factors to generate optical noise. To acquire near-infrared fluorescence images and to compare fluorescence contrast under conditions of darkroom, interior light and surgical light, light emitting diodes (LEDs) sources that have peak wavelength at 740, 760 and 780 nm respectively were used as excitation light sources. In addition, short-pass filter which has transmission edge at 775 nm has been applied to minimize the optical noise in each external noise factor. By comparing contrast of each image before and after use of the short-pass filter, we confirmed that optical noise reduced 49%, 56% and 66% in external noise factors respectively.
出处 《Journal of Biomedical Science and Engineering》 2015年第1期56-65,共10页 生物医学工程(英文)
关键词 NEAR-INFRARED FLUORESCENCE Optical Noise FILTERING Near-Infrared Fluorescence Optical Noise Filtering
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部